2906300 Phoenix Contact DC/DC Converters
Part#:2906300
Manufacturer:Phoenix Contact
Category:DC/DC Converters
Product Lifecycle:Active
Get a quick Quote!
Primary-switched UNO DC/DC converter with wide range input, for DIN rail mounting, input: 350 ... 900 V DC, output: 24Â VÂ DC/60Â W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2906300 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 90 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (operation) -25 °C ... 70 °C (> 55° C derating : 2.5%/K)
- Degree of pollution 2
- Current consumption 0.19 A (350 V DC)
- Nominal output voltage 24 V DC ±1 %
- Recommended breaker for input protection 1 A (Characteristic gPV or comparable)
- Connection in series No
- Residual ripple < 20 mVPP (with nominal values)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Net weight 0.3 kg
- Insulation voltage input/output 8 kV DC (type test)
- Assembly instructions alignable: 0Â mm horizontally, 30Â mm vertically
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 2.5 mm²
- Depth 84 mm
- Installation distance top/bottom 30 mm / 30 mm (≤ 70 °C)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 350 VÂ DC ... 900 VÂ DC
- Inrush current < 1 A (typical)
- Nominal output current (IN) 2.5 A (-25 °C ... 55 °C)
- Feedback voltage resistance < 35 VÂ DC
- Protection against overvoltage at the output (OVP) < 35 VÂ DC
- Typical response time < 1 s
- Efficiency > 90 %
- Housing material Polycarbonate
- Connection method Screw connection
- Conductor cross section solid max. 2.5 mm²
- Screw thread M3
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- UL approvals ULÂ 1741
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Test field strength 10 V/m
- Output 1 kV (Test Level 2 - symmetrical)
- Conducted interference ENÂ 61000-4-6
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 10.0.1 27210901
- Protection class II
- Foot latch material POM (Polyoxymethylen)
- Conductor cross section AWG min. 24
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard - Electrical safety IECÂ 62109-1
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Discharge in air 8 kV (Test Level 3)
- Fast transients (burst) ENÂ 61000-4-4
- Voltage dips ENÂ 61000-4-11
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27242213
- UNSPSC 13.2 39121004
- UNSPSC 19.0 39121004
- Width 55 mm
- Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
- Degree of protection IP20
- Ambient temperature (start-up type tested) -40 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Dielectric strength maximum ≤ 1050 V DC
- Input voltage range 300 VÂ DC ... 1000 VÂ DC
- Derating 55 °C ... 70 °C (2.5%/K)
- Connection in parallel Yes, for redundancy and increased capacity
- Output power 60 W
- Maximum power dissipation in no-load condition < 0.5 W
- Power loss nominal load max. < 6.5 W
- MTBF (IEC 61709, SN 29500) > 1160000 h (40 °C)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 8 mm
- Standard - Safety of power converters for use in photovoltaic power systems IECÂ 62109-1
- Electrostatic discharge EN 61000-4-2
- Frequency range 10 kHz ... 80 MHz
- Comments Criterion A
- Surge voltage load (surge) ENÂ 61000-4-5
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27210901
- ECLASS 6.0 27049005
- ETIM 6.0 EC002046
- Conductor cross section AWG max. 14
- EMC requirements for noise emission ENÂ 61000-6-3
- Mains variation/undervoltage ENÂ 61000-4-11
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Contact discharge 6 kV (Test Level 3)
- Electromagnetic HF field ENÂ 61000-4-3
- Input 2 kV (Test Level 3 - symmetrical)
- Voltage 10 V (Test Level 3)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 9.0 27210901
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?