Limit value switch with Ex i input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connectio

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2906165 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width
    12.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Depth
    114.5 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Status display
    Green LED (supply voltage, PWR)
  • Designation
    Systematic Capability
  • Test voltage
    2.5 kV AC (50 Hz, 1 min.)
  • Input voltage Ui
    30 V (Current and voltage input)
  • Height
    116 mm
  • Degree of protection
    IP20
  • Signal input
    Intrinsically safe
  • Current input signal
    0.2 mA ... 20 mA
  • Contact type
    1 changeover contact
  • Contact material
    AgSnO2, hard gold-plated
  • Typical current consumption
    38 mA (24 V DC)
  • Power consumption
    ≤ 1.2 W
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Maximum transmission error
    0.1 %
  • Maximum temperature coefficient
    0.01 %/K
  • Interference emission
    EN 61000-6-4
  • Housing material
    PA 6.6-FR
  • Input power Pi
    900 mW (Current and voltage input)
  • Max. internal inductance Li
    negligible
  • Identification
    3
  • Vibration
    A
  • ECLASS 10.0.1
    27210120
  • ECLASS 5.1
    27210100
  • ETIM 6.0
    EC002653
  • Ambient temperature (operation)
    -20 °C ... 65 °C (Any mounting position)
  • Voltage input signal
    0.1 V ... 10 V
  • Switching hysteresis
    off: approx. 0.5 %, on: approx. 1 %
  • Mechanical service life
    ≤ 107 cycles
  • Max. current consumption
    90 mA (10 V DC)
  • Stripping length
    8 mm
  • Connection name
    Test socket
  • Max. diameter
    2 mm
  • Overvoltage category
    II
  • Rated insulation voltage
    300 Vrms
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • Input current Ii
    120 mA (Current and voltage input)
  • Max. output power Po
    0 mW (Current input)
  • Conformance
    CE-compliant, additionally EN 61326
  • ATEX
     II (1) G [Ex ia Ga] IIC
  • Certificate
    TÜV Rheinland 968/FSP 1481.00/17
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27210100
  • ECLASS 9.0
    27210120
  • Maximum altitude
    ≤ 2000 m
  • Input resistance of voltage input
    > 100 kΩ
  • Output name
    Relay output
  • Nominal supply voltage
    24 V DC
  • Group
    IIC
  • UL, USA/Canada
    UL applied for
  • Humidity
    B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 11.0
    27210120
  • ECLASS 6.0
    27210100
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Line fault detection
    Break U < 50 mV, I < 0.1 mA
  • Input resistance current input
    < 28 Ω
  • Max. switching current
    ≤ 4 A AC (cos phi = 1)
  • Supply voltage range
    9.6 V DC ... 30 V DC (12 V DC ... 24 V DC (-20 % ... +25 %))
  • Power dissipation
    < 0.9 W
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 14
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 4.0
    27210100
  • ECLASS 7.0
    27210120
  • ETIM 7.0
    EC002653
  • Max. output voltage Uo
    0 V DC (Current input)
  • Safety-related maximum voltage Um
    253 V AC
  • Standards/regulations
    GB 3626.20
  • Additional text
    two-channel
  • Temperature
    B
  • EMC
    A
  • ECLASS 5.0
    27210100
  • ETIM 4.0
    EC002653
  • Degree of pollution
    2
  • Max. external capacitance Co
    35 µF
  • Step response (0–99%)
    ≤ 22 ms
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Max. output current Io
    0 mA (Current input)
  • Max. external inductivity Lo
    1 mH
  • Noise emission
    EN 61000-6-4
  • IECEx
    [Ex ia Ga] IIC
  • Max. internal capacitance Ci
    75 nF (for current input)
  • Electrical isolation
    375 V (Peak value in accordance with IEC/EN 60079-11)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?