2905577 Phoenix Contact Electrical Measuring & Monitoring Instruments

2905577 on Power Resource International
Phoenix Contact

Part#:2905577

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

3-way output signal conditioner for transmitting 0/4 ... 20 mA signals from the controller to a load located in the field with simultaneous 3-way electrical isolation between the input, output, and supply, with screw connection

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2905577 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    93.1 mm
  • Input voltage limitation
    < 2 V (20 mA)
  • Output name
    Current output
  • Transmission Behavior
    1:1 to input signal
  • Conductor cross section AWG
    26 ... 12
  • Limit frequency (3 dB)
    > 175 Hz
  • Protective circuit
    Transient protection
  • Noise emission
    EN 61000-6-4
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Standards/regulations
    EN 61000-4-6
  • Certificate
    DNV GL TAA000020N
  • Vibration
    B
  • ECLASS 11.0
    27210120
  • ECLASS 5.0
    27210100
  • UNSPSC 13.2
    39121008
  • UNSPSC 20.0
    39121008
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Number of inputs
    1
  • Load/output load current output
    ≤ 800 Ω (at 20 mA)
  • Nominal supply voltage
    24 V DC
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Maximum transmission error
    ≤ 0.1 % (of final value)
  • Step response (10-90%)
    < 2 ms
  • Degree of pollution
    2
  • Color
    green
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Designation
    Shipbuilding approval
  • EMC
    A
  • ECLASS 10.0.1
    27210120
  • ECLASS 4.1
    27210100
  • ETIM 7.0
    EC002653
  • Ambient temperature (operation)
    -20 °C ... 60 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Max. input current
    20 mA
  • Current output signal
    4 mA ... 20 mA
  • Screw thread
    M3
  • No. of channels
    1
  • Overvoltage category
    II
  • Mounting position
    any
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Identification
    UL 508 Listed
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27210100
  • ETIM 4.0
    EC002653
  • ECLASS 7.0
    27210120
  • UNSPSC 19.0
    39121008
  • Width
    6.2 mm
  • Depth
    101.2 mm
  • Maximum altitude
    ≤ 2000 m
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Degree of protection
    IP20
  • Current input signal
    4 mA ... 20 mA
  • Number of outputs
    1
  • Ripple
    < 20 mVrms
  • Supply voltage range
    19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Power consumption
    < 600 mW (at 24 V DC)
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Temperature coefficient, typical
    < 0.01 %/K
  • Electrical isolation
    Basic insulation according to EN 61010
  • Rated insulation voltage
    50 V AC/DC
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Assembly instructions
    To bridge the supply voltage, the DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Temperature
    B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27210100
  • ETIM 6.0
    EC002653
  • UNSPSC 21.0
    39121008
  • Stripping length
    12 mm
  • Connection method
    Screw connection
  • Maximum temperature coefficient
    < 0.01 %/K
  • Test voltage, input/output/supply
    1.5 kV (50 Hz, 1 min.)
  • Housing material
    PBT
  • Typical deviation from the measuring range final value
    3 %
  • Humidity
    B
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 6.0
    27210100
  • ECLASS 9.0
    27210120
  • UNSPSC 18.0
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?