2905249 Phoenix Contact Electrical Measuring & Monitoring Instruments

2905249 on Power Resource International
Phoenix Contact

Part#:2905249

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Push-in connection technology, standard configuration

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2905249 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Load/output load voltage output
    ≥ 10 kΩ
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • Typical cold point errors
    2 K (2 K + (0,2 K * ΔT))
  • Degree of pollution
    2
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Typical deviation from the measuring range final value
    0.05 %
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Max. output voltage
    approx. 12.3 V
  • Height
    109.81 mm
  • Configurable/programmable
    Yes
  • Number of outputs
    1
  • Max. output current
    24.6 mA
  • Ripple
    < 10 mVrms
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm² (with ferrule)
  • Maximum temperature coefficient
    ≤ 0.01 %/K
  • Overvoltage category
    II
  • Housing material
    PBT
  • Width
    6.2 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Sensor types that can be used (TC)
    B, C, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
  • Load/output load current output
    ≤ 600 Ω (at 20 mA)
  • Stripping length
    10 mm
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Rated insulation voltage
    300 V (effective)
  • Mounting position
    any
  • Depth
    119.2 mm
  • Degree of protection
    IP20 (not assessed by UL)
  • Voltage output signal
    0 V ... 5 V (via DIP switch)
  • Typical current consumption
    32.7 mA (24 V DC)
  • Power consumption
    ≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Protective circuit
    Transient protection
  • Conformance
    CE-compliant
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27200200
  • ECLASS 5.1
    27200200
  • ETIM 6.0
    EC002919
  • UNSPSC 7.0901
    39121008
  • UNSPSC 13.2
    41112105
  • UNSPSC 21.0
    41112105
  • ETIM 2.0
    EC001446
  • ETIM 4.0
    EC001446
  • UL, USA/Canada
    UL 508 Listed
  • ECLASS 11.0
    27210129
  • ECLASS 4.1
    27200200
  • UNSPSC 11
    39121008
  • UNSPSC 12.01
    39121008
  • UNSPSC 19.0
    41112105
  • Standards/regulations
    EN 61000-4-6
  • ECLASS 10.0.1
    27210129
  • ECLASS 7.0
    27200206
  • ECLASS 9.0
    27210129
  • UNSPSC 6.01
    30211506
  • UNSPSC 20.0
    41112105
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Identification
    C, EMC2
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 6.0
    27200200
  • ETIM 3.0
    EC001446
  • ETIM 7.0
    EC002919
  • UNSPSC 18.0
    41112105
  • ATEX
     II 3 G Ex nA IIC T4 Gc X
  • Certificate
    DNV GL 14445-15HH
  • Temperature measuring range
    -250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
  • Short-circuit current
    < 31.5 mA
  • Designation
    Shipbuilding approval
  • Current output signal
    0 mA ... 20 mA (via DIP switch)
  • Transmission error thermocouples
    0.1% * 600 K / set measuring range; 0.1% > 600 K (C, E, J, K, N, T, L, U, M Gost, L Gost)
  • Noise emission
    EN 61000-6-4
  • Connection method
    Push-in connection
  • ECLASS 5.0
    27200200

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts