2905139 Phoenix Contact Electrical Safety Devices

2905139 on Power Resource International
Phoenix Contact

Part#:2905139

Manufacturer:Phoenix Contact

Category:Electrical Safety Devices

Product Lifecycle:Active

Get a quick Quote!

Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2905139 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Operate threshold
    > 33 A
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Type of protection
    Surge protection
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Typical turn-off time
    < 30 ms
  • Load current range
    180 mA ... 3 A (see to derating)
  • Ambient temperature (operation)
    -5 °C ... 60 °C (observe derating)
  • Degree of protection
    IP20
  • Note
    The enable input is compatible with signals with blanking (semiconductor output signals with test pulse with max. 3 ms duration),unblanking pulses of max. 4 ms are tolerated without adversely affecting the safety function.
  • Rated actuating voltage UC
    24 V DC
  • Rated operating voltage Ue
    500 V AC
  • Mains frequency
    50/60 Hz
  • Response time
    < 0.5 s
  • Maximum power dissipation
    4.1 W
  • Connection method
    Push-in connection
  • Stripping length
    10 mm
  • Conductor cross section AWG
    24 ... 14
  • SCCR
    100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • FLA
    3 A (480 V AC)
  • Horsepower ratings
    0.5 hp (208 V AC)
  • Switching threshold
    9.6 V (“0” signal)
  • Operating voltage range
    42 V AC ... 550 V AC
  • Depth
    114 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Input name
    Enable input
  • Cooling time
    20 min. (for auto reset)
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Minimum power dissipation
    0.88 W
  • Operating voltage display
    Green LED
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Certificate
    NLDX.E228652
  • Identification
    ≤ 3
  • ECLASS 11.0
    27370905
  • ECLASS 5.1
    27024000
  • ETIM 3.0
    EC001037
  • UNSPSC 18.0
    25173902
  • UNSPSC 19.0
    25173902
  • Height
    107.5 mm
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Rated actuating current IC
    7 mA
  • Rated operating current Ie
    3 A (AC-51)
  • Leakage current
    0 mA
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Operating mode
    100% operating factor
  • Indication
    Red LED
  • Overvoltage category
    III
  • Designation
    Category (ISO 13849)
  • Standards/regulations
    IEC 60947-1
  • Category code
    NLDX / NRNT
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27021100
  • ECLASS 9.0
    27370905
  • ETIM 4.0
    EC001037
  • ETIM 6.0
    EC001037
  • UNSPSC 21.0
    25173902
  • Width
    22.5 mm
  • Maximum altitude
    ≤ 2000 m
  • Rated control supply current IS
    60 mA
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Output name
    AC output
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10
  • Motor starter type
    Reversing starter
  • Mounting type
    DIN rail mounting
  • Status display
    Yellow LED
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Degree of pollution
    2
  • Additional text
    Safe shutdown
  • Assembly instructions
    alignable, for spacing see derating
  • Connection name
    Load circuit
  • Rated surge voltage
    6 kV
  • Rated insulation voltage
    550 V
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • Group installation
    20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
  • ECLASS 10.0.1
    27370905
  • ECLASS 4.1
    27021100
  • ETIM 2.0
    EC001037
  • UNSPSC 13.2
    25173902
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27024000
  • ECLASS 6.0
    27024000
  • ECLASS 7.0
    27024002
  • ETIM 7.0
    EC001037
  • UNSPSC 20.0
    25173902

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?