Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2905138 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Input name
    Enable input
  • Rated actuating current IC
    7 mA
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Operating voltage range
    42 V AC ... 550 V AC
  • Load current range
    75 mA ... 600 mA (see to derating)
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Status display
    Yellow LED
  • Width
    22.5 mm
  • Maximum altitude
    ≤ 2000 m
  • Note
    The enable input is compatible with signals with blanking (semiconductor output signals with test pulse with max. 3 ms duration),unblanking pulses of max. 4 ms are tolerated without adversely affecting the safety function.
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Output name
    AC output
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10
  • Assembly instructions
    alignable, for spacing see derating
  • Minimum power dissipation
    0.88 W
  • Indication
    Red LED
  • Overvoltage category
    III
  • Degree of pollution
    2
  • Ambient temperature (operation)
    -5 °C ... 60 °C (observe derating)
  • Type of protection
    Surge protection
  • Rated control supply current IS
    60 mA
  • Typical turn-off time
    < 30 ms
  • Mains frequency
    50/60 Hz
  • Response time
    < 0.5 s
  • Mounting type
    DIN rail mounting
  • Operating voltage display
    Green LED
  • Stripping length
    10 mm
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • Certificate
    NLDX.E228652
  • FLA
    0.6 A (480 V AC)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27370905
  • ETIM 4.0
    EC001037
  • UNSPSC 13.2
    25173902
  • Depth
    114 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Switching threshold
    9.6 V (“0” signal)
  • Rated operating voltage Ue
    500 V AC
  • Cooling time
    20 min. (for auto reset)
  • Leakage current
    0 mA
  • Operate threshold
    > 10 A
  • Operating mode
    100% operating factor
  • Maximum power dissipation
    2.5 W
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 14
  • Rated insulation voltage
    550 V
  • Additional text
    Safe shutdown
  • Category code
    NLDX / NRNT
  • Horsepower ratings
    -
  • ECLASS 5.1
    27024000
  • ECLASS 6.0
    27024000
  • ETIM 7.0
    EC001037
  • UNSPSC 21.0
    25173902
  • Height
    107.5 mm
  • Degree of protection
    IP20
  • Rated actuating voltage UC
    24 V DC
  • Rated operating current Ie
    0.6 A (AC-51)
  • Motor starter type
    Reversing starter
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Connection name
    Load circuit
  • Rated surge voltage
    6 kV
  • Standards/regulations
    IEC 60947-1
  • SCCR
    100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27021100
  • ECLASS 9.0
    27370905
  • UNSPSC 20.0
    25173902
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Designation
    Category (ISO 13849)
  • Group installation
    20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
  • ECLASS 10.0.1
    27370905
  • ECLASS 5.0
    27024000
  • ETIM 6.0
    EC001037
  • ETIM 3.0
    EC001037
  • UNSPSC 19.0
    25173902
  • Identification
    ≤ 3
  • ECLASS 4.0
    27021100
  • ECLASS 7.0
    27024002
  • ETIM 2.0
    EC001037
  • UNSPSC 18.0
    25173902

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?