Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Push-in connection technology, standard configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2905028 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Voltage output signal 0 V ... 10 V (via DIP switch)
- Height 109.81 mm
- Number of inputs 1
- Current input signal 0 mA ... 20 mA (via DIP switch)
- Current output signal 0 mA ... 20 mA (via DIP switch)
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Conductor cross section AWG 24 ... 12 (flexible)
- Degree of pollution 2
- Overvoltage category II
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- Typical deviation from the measuring range final value 2.8 %
- UL, USA/Canada UL 508 Listed
- Temperature B
- Ambient temperature (operation) -40 °C ... 70 °C
- Maximum altitude ≤ 2000 m
- Configurable/programmable Yes
- Number of outputs 2
- Max. output voltage approx. 12.3 V
- Ripple < 20 mVPP (at 600 Ω)
- Stripping length 10 mm
- Conductor cross section solid 0.2 mm² ... 2.5 mm² (with ferrule)
- Rated insulation voltage 300 V
- Width 6.2 mm
- Electromagnetic compatibility Conformance with EMC directive
- Housing material PBT
- Mounting position any
- Designation Shipbuilding approval
- DNV GL-Temperature B
- Certificate DNV GL TAA000021E
- ECLASS 4.0 27210100
- ETIM 4.0 EC002653
- UNSPSC 6.01 30211506
- Max. input current 24 mA
- Short-circuit current ≤ 25 mA
- Typical current consumption 55 mA (24 V DC)
- Maximum transmission error 0.05 % (of final value)
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- Noise emission EN 61000-6-4
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- Standards/regulations EN 61000-4-6
- DNV GL-Humidity B
- Depth 119.2 mm
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- DNV GL-EMC A
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- max. input voltage 12 V
- Input resistance current input approx. 50 Ω (+0.7 V for test diode)
- Load/output load current output ≤ 600 Ω (per channel)
- Nominal supply voltage 24 V DC
- Connection method Push-in connection
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Maximum temperature coefficient 0.01 %/K
- Color gray
- Degree of protection IP20 (not assessed by UL)
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Voltage input signal 0 V ... 10 V (via DIP switch)
- Input resistance of voltage input > 120 kΩ
- Max. output current 24.6 mA
- Load/output load voltage output ≥ 10 kΩ
- Power consumption 1.5 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
- No. of channels 2
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- DNV GL-Vibration A
- Identification UL 508 Listed
- Vibration A
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 6.0 27210100
- UNSPSC 12.01 39121008
- UNSPSC 18.0 39121008
- ECLASS 10.0.1 27210120
- Conformance CE-compliant
- ATEX II 3 G Ex nA IIC T4 Gc X
- EMC A
- ECLASS 5.1 27210100
- UNSPSC 11 39121008
- Humidity B
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 11.0 27210120
- ETIM 6.0 EC002653
- UNSPSC 7.0901 39121008
- UNSPSC 20.0 39121008
- UNSPSC 13.2 39121008
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27210100
- ECLASS 7.0 27210120
- ETIM 7.0 EC002653
- UNSPSC 21.0 39121008
- ECLASS 5.0 27210100
- ECLASS 9.0 27210120
- UNSPSC 19.0 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?