Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Screw connection technology, standard configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2905026 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- ECLASS 5.1 27210100
- Height 109.81 mm
- Configurable/programmable Yes
- Load/output load voltage output ≥ 10 kΩ
- Maximum temperature coefficient 0.01 %/K
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Stripping length 10 mm
- UNSPSC 20.0 39121008
- Maximum transmission error 0.05 % (of final value)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- max. input voltage 12 V
- Nominal supply voltage 24 V DC
- Short-circuit current ≤ 25 mA
- Power consumption 1.5 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
- No. of channels 2
- Color gray
- UNSPSC 19.0 39121008
- Ambient temperature (operation) -40 °C ... 70 °C
- Standards/regulations EN 61000-4-6
- Conformance CE-compliant
- DNV GL-Vibration A
- Certificate DNV GL TAA000021E
- ETIM 6.0 EC002653
- Depth 119.2 mm
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- Housing material PBT
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- REACh SVHC Lead 7439-92-1
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Temperature B
- Voltage output signal 0 V ... 10 V (via DIP switch)
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- DNV GL-EMC A
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- Humidity B
- ECLASS 11.0 27210120
- Input resistance of voltage input > 120 kΩ
- Conductor cross section solid 0.2 mm² ... 1.5 mm² (with ferrule)
- Voltage input signal 0 V ... 10 V (via DIP switch)
- Input resistance current input approx. 50 Ω (+0.7 V for test diode)
- Current input signal 0 mA ... 20 mA (via DIP switch)
- Max. output current 24.6 mA
- Electromagnetic compatibility Conformance with EMC directive
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Noise emission EN 61000-6-4
- Max. output voltage approx. 12.3 V
- Overvoltage category II
- Conductor cross section AWG 24 ... 12 (flexible)
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- Typical deviation from the measuring range final value 2.8 %
- Max. input current 24 mA
- Load/output load current output ≤ 600 Ω (per channel)
- Screw thread M3
- Designation Shipbuilding approval
- Vibration A
- Maximum altitude ≤ 2000 m
- Ripple < 20 mVPP (at 600 Ω)
- Torque 0.5 Nm ... 0.6 Nm
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- ATEX II 3 G Ex nA IIC T4 Gc X
- Identification UL 508 Listed
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 6.0 27210100
- ECLASS 7.0 27210120
- UNSPSC 13.2 39121008
- UNSPSC 12.01 39121008
- Width 6.2 mm
- Number of inputs 1
- Number of outputs 2
- Connection method Screw connection
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- UL, USA/Canada UL 508 Listed
- ECLASS 4.0 27210100
- ETIM 4.0 EC002653
- ETIM 7.0 EC002653
- Degree of protection IP20 (not assessed by UL)
- Current output signal 0 mA ... 20 mA (via DIP switch)
- Typical current consumption 55 mA (24 V DC)
- Rated insulation voltage 300 V
- ECLASS 5.0 27210100
- UNSPSC 18.0 39121008
- Degree of pollution 2
- Mounting position any
- DNV GL-Temperature B
- DNV GL-Humidity B
- EMC A
- ECLASS 10.0.1 27210120
- ECLASS 9.0 27210120
- UNSPSC 11 39121008
- UNSPSC 21.0 39121008
- ECLASS 4.1 27210100
- UNSPSC 6.01 30211506
- UNSPSC 7.0901 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?