2905012 Phoenix Contact DC/DC Converters
Part#:2905012
Manufacturer:Phoenix Contact
Category:DC/DC Converters
Product Lifecycle:Active
Get a quick Quote!
Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (selective fuse breaking) technology, input: 96 - 110 V DC, output: 24 V DC/10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2905012 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 48 mm
- Height with alternative assembly 130 mm
- Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
- Ambient temperature (start-up type tested) -40 °C
- Degree of protection IP20
- Degree of pollution 2
- Input voltage range 67.2 V DC ... 154 V DC
- Input fuse 10 A 150 V DC (internal (device protection))
- Protective circuit/component Varistor
- POWER BOOST (IBoost) 12.5 A (-40°C ... 40°C permanent, UOUT = 24 V DC )
- Protection against overvoltage at the output (OVP) < 35 V DC
- Max. capacitive load unlimited
- Residual ripple < 20 mVPP
- Protection class I
- Conductor cross section flexible min. 0.2 mm²
- Screw thread M3
- Contact discharge 8 kV (Test Level 4)
- Net weight 0.9 kg
- Connection method Screw connection
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG max. 12
- Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
- UL approvals UL/C-UL listed UL 508
- Electrostatic discharge EN 61000-4-2
- Output 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 5.1 27210900
- ECLASS 9.0 27210901
- UNSPSC 20.0 39121041
- Depth 125 mm
- Depth with alternative assembly 51 mm
- Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)
- Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Current consumption 3.5 A (96 V DC)
- Mains buffering time typ. 10 ms (96 V DC)
- Nominal output voltage 24 V DC ±1 %
- Nominal output current (IN) 10 A (-40 °C ... 60 °C)
- Derating 60 °C ... 70 °C (2.5%/K)
- Feedback voltage resistance 35 V DC
- Power loss nominal load max. 22 W (UIN 110 V DC)
- Insulation voltage input/output 1.5 kV (type test)
- Conductor cross section flexible max. 2.5 mm²
- EMC requirements for noise emission EN 61000-6-3
- Rail applications EN 50121-4
- Frequency range 0.15 MHz ... 80 MHz
- Input 2 kV (Test Level 4 - symmetrical)
- Voltage 10 V (Test Level 3)
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27210900
- ETIM 6.0 EC002046
- UNSPSC 21.0 39121041
- Height 130 mm
- Width with alternative assembly 122 mm
- Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) 100 % (at 25 °C, non-condensing)
- Nominal input voltage range 96 V DC ... 110 V DC
- Inrush current < 10 A (typical)
- Type of protection Transient surge protection
- Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
- Selective Fuse Breaking (ISFB) 60 A (12 ms)
- Connection in series yes
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Peak switching voltages nominal load < 10 mVPP (20 MHz)
- MTBF (IEC 61709, SN 29500) > 1357000 h (25 °C)
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section AWG min. 24
- Standard – Safety extra-low voltage EN 60950-1 (SELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Test field strength 10 V/m (Test Level 3)
- Surge voltage load (surge) EN 61000-4-5
- I/O/S asymmetrical
- ECLASS 11.0 27210901
- ECLASS 7.0 27210901
- UNSPSC 18.0 39121041
- Signal 1 kV (Test Level 2 - asymmetrical)
- ECLASS 10.0.1 27210901
- ECLASS 5.0 27210900
- UNSPSC 13.2 39121041
- ETIM 7.0 EC002046
- Standard - Safe isolation DIN VDE 0100-410
- Comments Criterion A
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 6.0 27210900
- UNSPSC 19.0 39121041
- Maximum power dissipation in no-load condition 4 W (UIN 110 V DC)
- Conductor cross section solid min. 0.2 mm²
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Fast transients (burst) EN 61000-4-4
- ECLASS 4.0 27210900
- Mounting position horizontal DIN rail NS 35, EN 60715
- EMC requirements for noise immunity EN 61000-6-1
- Discharge in air 15 kV (Test Level 4)
- Active current limitation 18 A
- Efficiency > 92 % (UIN 96 V DC / UOUT 24 V DC)
- Connection in parallel Yes, for redundancy and increased capacity
- Stripping length 7 mm
- Electromagnetic HF field EN 61000-4-3
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?