2905011 Phoenix Contact DC/DC Converters
Part#:2905011
Manufacturer:Phoenix Contact
Category:DC/DC Converters
Product Lifecycle:Active
Get a quick Quote!
Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (Selective Fuse Breaking) technology, input: 60-72 V DC, output 24 V DC / 10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2905011 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 48 mm
- UNSPSC 18.0 39121041
- Height 130 mm
- Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
- Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Current consumption 5.6 A (60 V DC)
- Nominal output voltage 24 V DC ±1 %
- POWER BOOST (IBoost) 12.5 A (-40°C ... 40°C permanent, UOUT = 24 V DC )
- Connection in parallel Yes, for redundancy and increased capacity
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Maximum power dissipation in no-load condition 4 W (UIN 60 V DC)
- Power loss nominal load max. 24 W (UIN 60 V DC)
- Protection class I
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Connection method Screw connection
- Conductor cross section AWG min. 24
- EMC requirements for noise immunity EN 61000-6-1
- EMC requirements for noise emission EN 61000-6-3
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Rail applications EN 50121-4
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electromagnetic HF field EN 61000-4-3
- Test field strength 10 V/m (Test Level 3)
- Comments Criterion A
- I/O/S asymmetrical
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27210901
- ECLASS 5.0 27210900
- ECLASS 9.0 27210901
- Depth 125 mm
- Depth with alternative assembly 51 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) 100 % (at 25 °C, non-condensing)
- Climatic class 3K3 (in acc. with EN 60721)
- Inrush current < 9 A (typical)
- Protective circuit/component Varistor
- Selective Fuse Breaking (ISFB) 60 A (12 ms)
- Connection in series yes
- Feedback voltage resistance 35 V DC
- Peak switching voltages nominal load < 10 mVPP (20 MHz)
- Efficiency > 91 % (UIN 60 V DC / UOUT 24 V DC)
- MTBF (IEC 61709, SN 29500) > 1349000 h (25 °C)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG max. 12
- Stripping length 7 mm
- Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
- Standard – Safety extra-low voltage EN 60950-1 (SELV)
- Electrostatic discharge EN 61000-4-2
- Contact discharge 8 kV (Test Level 4)
- Fast transients (burst) EN 61000-4-4
- Signal 1 kV (Test Level 2 - asymmetrical)
- Surge voltage load (surge) EN 61000-4-5
- Conducted interference EN 61000-4-6
- ECLASS 10.0.1 27210901
- ECLASS 4.0 27210900
- ECLASS 5.1 27210900
- ETIM 6.0 EC002046
- UNSPSC 19.0 39121041
- Height with alternative assembly 130 mm
- Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
- Ambient temperature (start-up type tested) -40 °C
- Nominal input voltage range 60 V DC ... 72 V DC
- Input fuse 10 A 150 V DC (internal (device protection))
- Type of protection Transient surge protection
- Nominal output current (IN) 10 A (-40 °C ... 60 °C)
- Protection against overvoltage at the output (OVP) < 35 V DC
- Max. capacitive load unlimited
- Active current limitation 18 A
- Net weight 1 kg
- Insulation voltage input/output 1.5 kV (type test)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible max. 2.5 mm²
- Screw thread M3
- Standard - Safe isolation DIN VDE 0100-410
- UL approvals UL/C-UL listed UL 508
- Discharge in air 15 kV (Test Level 4)
- Frequency range 9 kHz ... 80 MHz
- Input 2 kV (Test Level 4 - symmetrical)
- Output 1 kV (Test Level 3 - symmetrical)
- Voltage 10 V (Test Level 3)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 4.1 27210900
- ECLASS 6.0 27210900
- ECLASS 7.0 27210901
- ETIM 7.0 EC002046
- Width with alternative assembly 122 mm
- Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
- Degree of protection IP20
- Degree of pollution 2
- Input voltage range 42 V DC ... 96 V DC
- Mains buffering time typ. 10 ms (60 V DC)
- Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
- Derating 60 °C ... 70 °C (2.5%/K)
- Residual ripple < 20 mVPP
- UNSPSC 13.2 39121041
- UNSPSC 20.0 39121041
- UNSPSC 21.0 39121041
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?