2905009 Phoenix Contact DC/DC Converters
Part#:2905009
Manufacturer:Phoenix Contact
Category:DC/DC Converters
Product Lifecycle:Active
Get a quick Quote!
Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (Selective Fuse Breaking) technology, input: 60-72 V DC, output 24 V DC / 10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2905009 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 130 mm
- Depth with alternative assembly 51 mm
- Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)
- Degree of protection IP20
- Degree of pollution 2
- Width with alternative assembly 122 mm
- Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Inrush current < 9 A (typical)
- Protective circuit/component Varistor
- Selective Fuse Breaking (ISFB) 60 A (12 ms)
- Feedback voltage resistance 35 V DC
- Connection in parallel Yes, for redundancy and increased capacity
- Max. capacitive load unlimited
- MTBF (IEC 61709, SN 29500) > 1349000 h (25 °C)
- Insulation voltage input/output 1.5 kV (type test)
- Conductor cross section AWG min. 24
- EMC requirements for noise emission EN 61000-6-3
- Standard – Safety extra-low voltage EN 60950-1 (SELV)
- Discharge in air 15 kV (Test Level 4)
- Comments Criterion A
- Conducted interference EN 61000-4-6
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27210900
- ECLASS 5.1 27210900
- UNSPSC 20.0 39121041
- Conductor cross section solid max. 2.5 mm²
- Connection method Screw connection
- Conductor cross section flexible max. 2.5 mm²
- Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field EN 61000-4-3
- Surge voltage load (surge) EN 61000-4-5
- Voltage 10 V (Test Level 3)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.1 27210900
- ECLASS 7.0 27210901
- ETIM 6.0 EC002046
- UNSPSC 21.0 39121041
- Width 48 mm
- Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
- Ambient temperature (start-up type tested) -40 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Nominal input voltage range 60 V DC ... 72 V DC
- Type of protection Transient surge protection
- Input fuse 10 A 150 V DC (internal (device protection))
- Nominal output current (IN) 10 A (-40 °C ... 60 °C)
- Protection against overvoltage at the output (OVP) < 35 V DC
- Power loss nominal load max. 24 W (UIN 60 V DC)
- Efficiency > 91 % (UIN 60 V DC / UOUT 24 V DC)
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section flexible min. 0.2 mm²
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Contact discharge 8 kV (Test Level 4)
- Input 2 kV (Test Level 4 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 11.0 27210901
- ECLASS 9.0 27210901
- UNSPSC 18.0 39121041
- UNSPSC 19.0 39121041
- Depth 125 mm
- Height with alternative assembly 130 mm
- Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Current consumption 5.6 A (60 V DC)
- Mains buffering time typ. 10 ms (60 V DC)
- Nominal output voltage 24 V DC ±1 %
- Derating 60 °C ... 70 °C (2.5%/K)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Residual ripple < 20 mVPP
- Peak switching voltages nominal load < 10 mVPP (20 MHz)
- Protection class I
- Conductor cross section AWG max. 12
- EMC requirements for noise immunity EN 61000-6-1
- Rail applications EN 50121-4
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Test field strength 10 V/m (Test Level 3)
- Output 1 kV (Test Level 3 - symmetrical)
- ECLASS 10.0.1 27210901
- ECLASS 6.0 27210900
- ETIM 7.0 EC002046
- Input voltage range 42 V DC ... 96 V DC
- Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
- POWER BOOST (IBoost) 12.5 A (-40°C ... 40°C permanent, UOUT = 24 V DC )
- Connection in series yes
- Active current limitation 18 A
- Maximum power dissipation in no-load condition 4 W (UIN 60 V DC)
- Net weight 1 kg
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid min. 0.2 mm²
- Stripping length 7 mm
- Screw thread M3
- Standard - Safe isolation DIN VDE 0100-410
- UL approvals UL/C-UL listed UL 508
- Frequency range 0.9 MHz ... 80 MHz
- Fast transients (burst) EN 61000-4-4
- Signal 1 kV (Test Level 2 - asymmetrical)
- I/O/S asymmetrical
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.0 27210900
- UNSPSC 13.2 39121041
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?