2904623 Phoenix Contact AC/DC Power Supplies
Part#:2904623
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/40 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904623 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Voltage 2.5 kV
- Depth 125 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Nominal input voltage range 3x 400 VÂ AC ... 500 VÂ AC
- Discharge current to PE < 3.5 mA
- Type of protection Transient surge protection
- Nominal output current (IN) 40 A
- Control deviation < 0.5 % (Static load change 10Â % ... 90Â %)
- Residual ripple < 50 mVPP (with nominal values)
- MTBF (IEC 61709, SN 29500) > 849000 h (25 °C)
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
- Standard - safety for equipment for measurement, control, and laboratory use IECÂ 61010-1
- UL approvals UL Listed ULÂ 508
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Harmonic currents ENÂ 61000-3-2
- DNVÂ GL noise radiation Class B
- Comments Criterion A
- Input 2 kV (Test Level 4 - symmetrical)
- Installation distance right/left 5 mm / 5 mm
- Climatic class 3K3 (in acc. with EN 60721)
- AC frequency range 50 Hz ... 60 Hz -10Â % ... +10Â %
- Power factor (cos phi) 0.95
- Protective circuit/component Varistor, gas-filled surge arrester
- Dynamic Boost (IDyn.Boost) 60 A (5 s)
- Connection in series yes
- Output power 960 W
- Insulation voltage input/output 4 kV AC (type test)
- Protection class I
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section AWG max. 16
- EMC requirements, power plant IECÂ 61850-3
- Standard - Safety of transformers ENÂ 61558-2-16
- Rail applications ENÂ 50121-3-2
- SIQ BG (type approved)
- Additional text Test Level 2
- Electrostatic discharge EN 61000-4-2
- Fast transients (burst) ENÂ 61000-4-4
- I/O/S asymmetrical
- Power frequency magnetic field EN 61000-4-8
- Damped oscillating magnetic field ENÂ 61000-4-10
- Test level 6 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 9.0 27040701
- Contact discharge 8 kV (Test Level 4)
- Height 130 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Degree of pollution 2
- Input voltage range 3x 400 V AC ... 500 V AC -20 % ... +10 %
- Nominal power consumption 1217 VA
- Inrush current typ. 1.5 A (at 25 °C)
- Nominal output voltage 24 VÂ DC
- Selective Fuse Breaking (ISFB) 215 A (15 ms)
- Feedback voltage resistance ≤ 35 V DC
- Typical response time 300 ms (from SLEEP MODE)
- Efficiency typ. 95.7 % (400Â VÂ AC)
- Insulation voltage output / PE 0.5 kV DC (type test)
- Conductor cross section solid max. 1 mm²
- Conductor cross section flexible min. 0.2 mm²
- Standard - Electrical safety IECÂ 61010-2-201Â (SELV)
- Standard - Safe isolation IECÂ 61558-2-16
- Mains variation/undervoltage SEMIÂ F47-0706, ENÂ 61000-4-11
- Noise emission EN 55016
- Frequency range 50 Hz ... 60 Hz
- Surge voltage load (surge) ENÂ 61000-4-5
- Voltage dip 0 %
- Test level 2 150 Hz 1.5 kHz (Test Level 4)
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- ETIM 7.0 EC002540
- Width 120 mm
- Degree of protection IP20
- Ambient temperature (start-up type tested) -40 °C
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Current consumption 3x 1.8 A (400Â VÂ AC)
- Mains buffering time typ. 28 ms (3x 400 V AC)
- Static Boost (IStat.Boost) 45 A
- Derating > 60 °C ... 70 °C (2.5%/K)
- Maximum power dissipation in no-load condition < 5 W (400Â VÂ AC)
- Environmental protection directive RoHS Directive 2011/65/EU
- Insulation voltage input / PE 3.5 kV AC (type test)
- Conductor cross section AWG min. 24
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Shipbuilding approval DNVÂ GL, BV, LR, ABS
- Flicker ENÂ 61000-3-3
- DNVÂ GL conducted interference Class A
- Electromagnetic HF field ENÂ 61000-4-3
- Signal 4 kV (Test Level 2 - asymmetrical)
- Frequency 50 Hz
- Number of periods 0,5 / 1 / 5 / 50 / 250 periods
- Test level 4 15 kHz 150 kHz (Test Level 4)
- Input, output (test level 2) 10 MHz
- Criterion A Normal operating behavior within the specified limits.
- REACh SVHC Lead 7439-92-1
- ETIM 6.0 EC002540
- Installation distance top/bottom 50 mm / 50 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Frequency range (fN) 50 Hz ... 60 Hz -10Â % ... +10Â %
- Recommended breaker for input protection 3x 4 A ... 20 A (Characteristic B, C, D, K or comparable)
- Setting range of the output voltage (USet) 24 VÂ DC ... 29.5 VÂ DC (constant capacity)
- Connection in parallel Yes, for redundancy and increased capacity
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Net weight 2.6 kg
- Power loss nominal load max. < 45 W (400Â VÂ AC)
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- EMC requirements for noise emission ENÂ 61000-6-3
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Conducted noise emission EN 55016
- Discharge in air 15 kV (Test Level 4)
- Test field strength 100 A/m
- Output 1 kV (Test Level 3 - symmetrical)
- Conducted interference ENÂ 61000-4-6
- Pulse-shape magnetic field EN 61000-4-9
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 4)
- Input, output (test level 3) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- ECLASS 10.0.1 27040701
- Voltage dips ENÂ 61000-4-11
- Test level 1 15 Hz 150 Hz (Test Level 4)
- Test level 3 1.5 kHz 15 kHz (Test Level 4)
- Attenuated oscillating wave EN 61000-4-18
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 11.0 27040701
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?