2904621 Phoenix Contact AC/DC Power Supplies
Part#:2904621
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904621 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width with alternative assembly 122 mm
- Installation distance right/left 5 mm / 5 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Degree of pollution 2
- Input voltage range 3x 400 V AC ... 500 V AC -20 % ... +10 %
- Current consumption 3x 0.5 A (400 V AC)
- Mains buffering time typ. 29 ms (3x 400 V AC)
- Nominal output voltage 24 V DC
- Derating > 60 °C ... 70 °C (2.5%/K)
- Connection in parallel Yes, for redundancy and increased capacity
- Residual ripple < 75 mVPP (with nominal values)
- Power loss nominal load max. < 19 W (400 V AC)
- MTBF (IEC 61709, SN 29500) > 1034000 h (25 °C)
- Connection method Push-in connection
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 16
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Width 50 mm
- Depth with alternative assembly 53 mm
- Ambient temperature (start-up type tested) -40 °C
- Nominal input voltage range 3x 400 V AC ... 500 V AC
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- Power factor (cos phi) 0.91
- Protective circuit/component Varistor, gas-filled surge arrester
- Nominal output current (IN) 10 A
- Feedback voltage resistance ≤ 35 V DC
- Control deviation < 0.5 % (Static load change 10 % ... 90 %)
- Efficiency typ. 93 % (400 V AC)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 24
- Standard - Safety of transformers IEC 61558-2-16 pending
- Standard - Safe isolation IEC 61558-2-16 pending
- CSA CAN/CSA-C22.2 No. 60950-1-07
- SIQ BG (type approved)
- Conducted noise emission EN 55016
- DNV GL noise radiation Class B
- Discharge in air 15 kV (Test Level 4)
- Electromagnetic HF field EN 61000-4-3
- Signal 4 kV (Test Level 4 - asymmetrical)
- Voltage dips EN 61000-4-11
- Height 130 mm
- Installation distance top/bottom 50 mm / 50 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Inrush current typ. 3 A (at 25 °C)
- Recommended breaker for input protection 3x 4 A ... 20 A (Characteristic B, C or comparable)
- Selective Fuse Breaking (ISFB) 60 A (15 ms)
- Output power 240 W
- Net weight 0.9 kg
- Environmental protection directive RoHS Directive 2011/65/EU
- Insulation voltage input / PE 3.5 kV AC (type test)
- Conductor cross section flexible max. 1.5 mm²
- Stripping length 8 mm
- EMC requirements, power plant IEC 61850-3
- Standard - power supply devices for low voltage with DC output EN 61204-3
- Rail applications EN 50121-3-2
- Noise emission EN 55016
- DNV GL conducted interference Class A
- Test field strength 110 A/m
- Comments Criterion A
- Conducted interference EN 61000-4-6
- I/O/S asymmetrical
- Number of periods 5 / 10 / 50 periods
- Test level 1 15 Hz 150 Hz (Test Level 4)
- Test level 3 1.5 kHz 15 kHz (Test Level 4)
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Depth 125 mm
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Discharge current to PE < 3.5 mA
- Nominal power consumption 274 VA
- Static Boost (IStat.Boost) 12.5 A
- Connection in series yes
- Typical response time 300 ms (from SLEEP MODE)
- Insulation voltage input/output 4 kV AC (type test)
- Protection class I
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- UL approvals UL Listed UL 508
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Flicker EN 61000-3-3
- Electrostatic discharge EN 61000-4-2
- Output 1 kV (Test Level 3 - symmetrical)
- Frequency 50 Hz
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Attenuated oscillating wave EN 61000-4-18
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 5.1 27242213
- UNSPSC 21.0 39121004
- Height with alternative assembly 130 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Type of protection Transient surge protection
- Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (constant capacity)
- Dynamic Boost (IDyn.Boost) 20 A (5 s)
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Maximum power dissipation in no-load condition < 5 W (400 V AC)
- Insulation voltage output / PE 0.5 kV DC (type test)
- Conductor cross section solid max. 1 mm²
- EMC requirements for noise emission EN 61000-6-3
- HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Shipbuilding approval DNV GL, PRS, BV, LR, ABS
- Additional text Test Level 2
- Frequency range 50 Hz ... 60 Hz
- Fast transients (burst) EN 61000-4-4
- Power frequency magnetic field EN 61000-4-8
- Voltage dip 40 %
- Test level 2 150 Hz 1.5 kHz (Test Level 4)
- Test level 4 15 kHz 150 kHz (Test Level 4)
- Test level 6 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Input, output (test level 3) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 6.0 27049005
- ECLASS 9.0 27040701
- Mains variation/undervoltage SEMI F47-0706, EN 61000-4-11
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Harmonic currents EN 61000-3-2
- Contact discharge 8 kV (Test Level 4)
- Input 2 kV (Test Level 4 - symmetrical)
- Surge voltage load (surge) EN 61000-4-5
- Voltage 2.5 kV
- Pulse-shape magnetic field EN 61000-4-9
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Test level 5 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 11.0 27040701
- ETIM 6.0 EC002540
- UNSPSC 20.0 39121004
- Damped oscillating magnetic field EN 61000-4-10
- Input, output (test level 2) 10 MHz
- China RoHS Environmentally Friendly Use Period = 25;
- UNSPSC 18.0 39121004
- Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- REACh SVHC Lead 7439-92-1
- ECLASS 10.0.1 27040701
- UNSPSC 13.2 39121004
- UNSPSC 19.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?