2904610 Phoenix Contact AC/DC Power Supplies
Part#:2904610
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched QUINT POWER power supply for DIN rail mounting with free choice of output characteristic curve and SFB (Selective Fuse Breaking) technology, input: 1-phase, output: 48 V DC / 5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904610 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth with alternative assembly 53 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Current consumption 3.4 A (100 V AC)
- Mains buffering time typ. 43 ms (120 V AC)
- Protective circuit/component Varistor, gas-filled surge arrester
- Nominal output voltage 48 V DC
- Static Boost (IStat.Boost) 6.25 A
- Residual ripple < 70 mVPP (with nominal values)
- Maximum power dissipation in no-load condition < 3 W (120 V AC)
- Efficiency typ. 92.3 % (120 V AC)
- Insulation voltage output / PE 0.5 kV DC (type test)
- Depth 125 mm
- Installation distance right/left 5 mm / 5 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Climatic class 3K3 (in acc. with EN 60721)
- Dielectric strength maximum 300 V AC 60 s
- Discharge current to PE < 3.5 mA
- Type of protection Transient surge protection
- Width with alternative assembly 122 mm
- Installation distance top/bottom 50 mm / 50 mm
- Degree of protection IP20
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Nominal power consumption 271 VA
- Recommended breaker for input protection 10 A ... 16 A (Characteristic B, C, D, K or comparable)
- Selective Fuse Breaking (ISFB) 30 A (15 ms)
- Derating > 60 °C ... 70 °C (2.5%/K)
- Connection in parallel Yes, for redundancy and increased capacity
- Protection against overvoltage at the output (OVP) ≤ 60 V DC
- Power loss nominal load max. < 19 W (120 V AC)
- Environmental protection directive RoHS Directive 2011/65/EU
- Protection class I
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section AWG min. 24
- Standard - Safety of transformers EN 61558-2-16
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- Standard - Safe isolation IEC 61558-2-16
- UL approvals UL Listed UL 508
- Conducted noise emission EN 55016
- Frequency range 50 Hz ... 60 Hz
- Fast transients (burst) EN 61000-4-4
- Signal 4 kV (Test Level 4 - asymmetrical)
- I/O/S asymmetrical
- Voltage dips EN 61000-4-11
- Damped oscillating magnetic field EN 61000-4-10
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- Width 50 mm
- Height with alternative assembly 130 mm
- Ambient temperature (start-up type tested) -40 °C
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 100 V AC ... 240 V AC
- Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
- Inrush current typ. 16 A (at 25 °C)
- Input fuse 8 A (slow-blow, internal)
- Nominal output current (IN) 5 A
- Connection in series yes
- Output power 240 W
- Typical response time 300 ms (from SLEEP MODE)
- Insulation voltage input/output 4 kV AC (type test)
- Connection method Push-in connection
- Conductor cross section flexible min. 0.2 mm²
- Height 130 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.1 27049002
- Setting range of the output voltage (USet) 48 V DC ... 56 V DC (constant capacity)
- Dynamic Boost (IDyn.Boost) 10 A (5 s)
- Feedback voltage resistance ≤ 60 V DC
- Control deviation < 0.5 % (Static load change 10 % ... 90 %)
- Net weight 1 kg
- MTBF (IEC 61709, SN 29500) > 1242000 h (25 °C)
- Insulation voltage input / PE 3.5 kV AC (type test)
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- EMC requirements for noise immunity EN 61000-6-1
- Stripping length 8 mm
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Rail applications EN 50121-3-2
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 8 kV (Test Level 4)
- Flicker EN 61000-3-3
- Test field strength 110 A/m
- Conducted interference EN 61000-4-6
- Voltage 2.5 kV
- Voltage dip 0 %
- Test level 2 150 Hz 1.5 kHz (Test Level 4)
- Test level 3 1.5 kHz 15 kHz (Test Level 4)
- Test level 6 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- REACh SVHC Lead 7439-92-1
- ETIM 6.0 EC002540
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section solid max. 1 mm²
- EMC requirements for noise emission EN 61000-6-3
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Harmonic currents EN 61000-3-2
- Electrostatic discharge EN 61000-4-2
- Input 2 kV (Test Level 4 - symmetrical)
- Output 1 kV (Test Level 3 - symmetrical)
- Power frequency magnetic field EN 61000-4-8
- Frequency 50 Hz
- Number of periods 0,5 / 1 / 5 / 50 / 250 periods
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Attenuated oscillating wave EN 61000-4-18
- Input, output (test level 2) 10 MHz
- Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- ECLASS 10.0.1 27040701
- ETIM 7.0 EC002540
- Conductor cross section AWG max. 16
- HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
- EMC requirements, power plant IEC 61850-3
- Mains variation/undervoltage SEMI F47-0706, EN 61000-4-11
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Noise emission EN 55016
- Discharge in air 15 kV (Test Level 4)
- Electromagnetic HF field EN 61000-4-3
- Comments Criterion A
- Additional text Test Level 2
- Pulse-shape magnetic field EN 61000-4-9
- Test level 1 15 Hz 150 Hz (Test Level 4)
- Test level 4 15 kHz 150 kHz (Test Level 4)
- Test level 5 16.7 Hz 50 Hz 60 Hz (Test Level 4)
- Input, output (test level 3) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 11.0 27040701
- ECLASS 9.0 27040701
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?