2904376 Phoenix Contact AC/DC Power Supplies
Part#:2904376
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched UNO power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/150 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904376 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- UNSPSC 18.0 39121004
- Width 37 mm
- Ambient temperature (start-up type tested) -25 °C
- Degree of pollution 2
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Input fuse 2.5 A (slow-blow, internal)
- Nominal output current (IN) 6.25 A (-25 °C ... 55 °C)
- Type of protection Transient surge protection
- Connection in series No
- Typical response time < 1 s
- Power loss nominal load max. < 9.7 W
- Net weight 0.5 kg
- Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
- Conductor cross section flexible max. 2.5 mm²
- Conductor cross section AWG max. 14
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Standard - Safe isolation DIN VDE 0100-410
- UL approvals UL/C-UL listed UL 508
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Discharge in air 8 kV (Test Level 3)
- Comments Criterion A
- Surge voltage load (surge) EN 61000-4-5
- Criterion A Normal operating behavior within the specified limits.
- Voltage 10 V (Test Level 3)
- Installation distance top/bottom 30 mm / 30 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Depth 125 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 85 V AC ... 264 V AC
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Protective circuit/component Varistor
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC ±1 %
- Derating 55 °C ... 70 °C (2.5%/K)
- Output power 150 W
- Efficiency typ. 91 % (120 V AC)
- Housing material Polycarbonate
- Conductor cross section solid min. 0.2 mm²
- Mounting position horizontal DIN rail NS 35, EN 60715
- Screw thread M3
- EMC requirements for noise emission EN 61000-6-3
- Stripping length 8 mm
- Mains variation/undervoltage EN 61000-4-11
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field EN 61000-4-3
- Frequency range 0.15 MHz ... 80 MHz
- Fast transients (burst) EN 61000-4-4
- Output 1 kV (Test Level 2 - symmetrical)
- Conducted interference EN 61000-4-6
- ECLASS 10.0.1 27040701
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.0 27049000
- ETIM 4.0 EC000599
- UNSPSC 19.0 39121004
- ETIM 7.0 EC002540
- Height 130 mm
- Degree of protection IP20
- Nominal input voltage range 100 V AC ... 240 V AC
- Current consumption 1.66 A (100 V AC)
- Nominal power consumption 164.7 VA
- Inrush current < 50 A (typical)
- Connection in parallel Yes, for redundancy and increased capacity
- Feedback voltage resistance < 35 V DC
- Residual ripple < 40 mVPP (with nominal values)
- Insulation voltage input/output 4 kV AC (type test)
- MTBF (IEC 61709, SN 29500) > 868000 h (40 °C)
- Conductor cross section solid max. 2.5 mm²
- Connection method Screw connection
- Conductor cross section AWG min. 24
- Standard - Safety of transformers EN 61558-2-16
- Standard - Electrical safety IEC 62368-1/VDE 0805 (SELV)
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 6 kV (Test Level 3)
- Test field strength 10 V/m (Test Level 3)
- Input 2 kV (Test Level 3 - symmetrical)
- Voltage dips EN 61000-4-11
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.0 27040700
- ECLASS 5.1 27049000
- ECLASS 9.0 27040701
- ETIM 6.0 EC002540
- UNSPSC 20.0 39121004
- UNSPSC 21.0 39121004
- Installation distance right/left 0 mm / 0 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- AC frequency range 50 Hz ... 60 Hz
- Mains buffering time > 20 ms (120 V AC)
- Power factor (cos phi) 0.97
- Nominal output voltage 24 V DC ±1 %
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Protection against overvoltage at the output (OVP) ≤ 35 V DC
- Maximum power dissipation in no-load condition < 1.2 W
- Protection class II (in closed control cabinet)
- Foot latch material POM (Polyoxymethylen)
- Conductor cross section flexible min. 0.2 mm²
- ECLASS 11.0 27040701
- ECLASS 4.1 27040700
- ECLASS 6.0 27049000
- ECLASS 7.0 27049002
- UNSPSC 13.2 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?