Primary-switched UNO power supply for DIN rail mounting, input: single-phase, output: 24 V DC/240 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904372 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Voltage dips EN 61000-4-11
- Width 45 mm
- Depth 125 mm
- Installation distance top/bottom 30 mm / 30 mm
- Ambient temperature (start-up type tested) -25 °C
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Nominal power consumption 260 VA
- Current consumption 2.69 A (100 V AC)
- Power factor (cos phi) 0.99
- Nominal output current (IN) 10 A (-25 °C ... 55 °C)
- Connection in parallel Yes, for redundancy and increased capacity
- Residual ripple < 50 mVPP (with nominal values)
- Power loss nominal load max. < 18.8 W
- Nominal output voltage 24 V DC ±1 %
- Connection in series No
- Protection against overvoltage at the output (OVP) ≤ 35 V DC
- Maximum power dissipation in no-load condition < 1.1 W
- Protection class I (in closed control cabinet)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 24
- Conductor cross section AWG max. 14
- Standard - Safety of transformers EN 61558-2-16
- Mains variation/undervoltage EN 61000-4-11
- Electrostatic discharge EN 61000-4-2
- Test field strength 10 V/m (Test Level 3)
- Output 1 kV (Test Level 2 - symmetrical)
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Climatic class 3K3 (in acc. with EN 60721)
- Degree of pollution 2
- Inrush current < 80 A (typical)
- Mains buffering time > 10 ms (120 V AC)
- Input fuse 5 A (slow-blow, internal)
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC ±1 %
- Control deviation change in load, static 10 % ... 90 %
- Insulation voltage input/output 4 kV AC (type test)
- Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
- Connection method Screw connection
- EMC requirements for noise emission EN 61000-6-3
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electromagnetic HF field EN 61000-4-3
- Input 2 kV (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27040701
- ECLASS 5.0 27049000
- ECLASS 5.1 27049000
- UNSPSC 18.0 39121004
- Type of protection Transient surge protection
- Feedback voltage resistance < 35 V DC
- Output power 240 W
- Efficiency typ. 90 % (120 V AC)
- Housing material Aluminum / polycarbonate
- Conductor cross section flexible max. 2.5 mm²
- Screw thread M3
- Standard - Safe isolation DIN VDE 0100-410
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Frequency range 0.15 MHz ... 80 MHz
- Conducted interference EN 61000-4-6
- ECLASS 6.0 27049000
- ETIM 4.0 EC000599
- UNSPSC 19.0 39121004
- Height 130 mm
- Degree of protection IP20
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Nominal input voltage range 100 V AC ... 240 V AC
- Input voltage range 85 V AC ... 264 V AC (< 95 V AC Derating 1 %/V)
- AC frequency range 50 Hz ... 60 Hz
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Protective circuit/component Varistor
- Derating 55 °C ... 70 °C (2.5%/K)
- Typical response time < 1 s
- Net weight 0.66 kg
- MTBF (IEC 61709, SN 29500) > 641000 h (40 °C)
- Conductor cross section flexible min. 0.2 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Discharge in air 8 kV (Test Level 3)
- Fast transients (burst) EN 61000-4-4
- UNSPSC 21.0 39121004
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 7.0 27049002
- UNSPSC 20.0 39121004
- Mounting position horizontal DIN rail NS 35, EN 60715
- Stripping length 8 mm
- UL approvals UL/C-UL listed UL 508
- Contact discharge 6 kV (Test Level 3)
- ECLASS 4.1 27040700
- ETIM 6.0 EC002540
- Voltage 10 V (Test Level 3)
- China RoHS Environmentally Friendly Use Period = 25;
- UNSPSC 13.2 39121004
- Conductor cross section solid max. 2.5 mm²
- Standard - Electrical safety IEC 62368-1/VDE 0805 (SELV)
- ECLASS 4.0 27040700
- ECLASS 9.0 27040701
- Comments Criterion A
- Surge voltage load (surge) EN 61000-4-5
- ECLASS 11.0 27040701
- ETIM 7.0 EC002540
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?