Primary-switched UNO POWER power supply for DIN rail mounting, input: 2-phase, output: 24 V DC/90 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2904371 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 84 mm
- Degree of pollution 2
- Current consumption 0.55 A (400Â VÂ AC)
- Mains buffering time > 65 ms (400Â VÂ AC)
- Power factor (cos phi) 0.48
- Installation distance top/bottom 30 mm / 30 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Input voltage range 2x 264 VÂ AC ... 575 VÂ AC
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Nominal output voltage 24 V DC ±1 %
- Connection in series No
- Power loss nominal load max. < 12 W
- Protection class II (in closed control cabinet)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible max. 2.5 mm²
- Standard - Electrical safety IECÂ 62368-1/VDEÂ 0805 (SELV)
- Width 55 mm
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Extended input voltage range in operation 2x 264 VÂ AC ... 320 VÂ AC (Derating 10 %)
- Nominal power consumption 211.3 VA
- Nominal output current (IN) 3.75 A
- Protection against overvoltage at the output (OVP) ≤ 35 V DC
- Net weight 0.32 kg
- Housing material Polycarbonate
- Assembly instructions alignable: 0Â mm horizontally, 30Â mm vertically
- Conductor cross section AWG min. 24
- EMC requirements for noise immunity ENÂ 61000-6-1
- Degree of protection IP20
- Climatic class 3K3 (in acc. with EN 60721)
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Input fuse 2 A (slow-blow, internal)
- Protective circuit/component Varistor
- Derating 55 °C ... 70 °C (2.5%/K)
- Output power 90 W
- Efficiency typ. 89 % (400Â VÂ AC)
- Insulation voltage input/output 4 kV AC (type test)
- Connection method Screw connection
- Conductor cross section AWG max. 14
- Screw thread M3
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Mains variation/undervoltage ENÂ 61000-4-11
- Electrostatic discharge EN 61000-4-2
- Test field strength 10 V/m
- Input 2 kV (Test Level 3 - symmetrical)
- Voltage 10 V (Test Level 3)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 11.0 27040701
- Height 90 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Nominal input voltage range 2x 400 VÂ AC ... 500 VÂ AC
- Inrush current < 30 A (typical)
- Type of protection Transient surge protection
- Connection in parallel no
- Residual ripple < 50 mVPP (with nominal values)
- Maximum power dissipation in no-load condition < 0.7 W
- MTBF (IEC 61709, SN 29500) > 828000 h (40 °C)
- Conductor cross section solid max. 2.5 mm²
- Stripping length 8 mm
- EMC requirements for noise emission ENÂ 61000-6-3
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- UL approvals UL/C-UL listed UL 508
- Discharge in air 8 kV (Test Level 3)
- Frequency range 10 kHz ... 80 MHz
- Output 1 kV (Test Level 2 - symmetrical)
- Voltage dips ENÂ 61000-4-11
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Feedback voltage resistance < 35 VÂ DC
- Foot latch material POM (Polyoxymethylen)
- Comments Criterion A
- ECLASS 5.0 27049000
- ECLASS 5.1 27049000
- UNSPSC 19.0 39121004
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Standard - Safety of transformers ENÂ 61558-2-16
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field ENÂ 61000-4-3
- Conducted interference ENÂ 61000-4-6
- ECLASS 10.0.1 27040701
- ECLASS 6.0 27049000
- UNSPSC 13.2 39121004
- UNSPSC 21.0 39121004
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- Surge voltage load (surge) ENÂ 61000-4-5
- ECLASS 7.0 27049002
- ECLASS 9.0 27040701
- ETIM 7.0 EC002540
- Contact discharge 6 kV (Test Level 3)
- Fast transients (burst) ENÂ 61000-4-4
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 4.1 27040700
- ETIM 6.0 EC002540
- UNSPSC 20.0 39121004
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- ECLASS 4.0 27040700
- ETIM 4.0 EC002540
- UNSPSC 18.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?