Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903918 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Depth
    114 mm
  • Maximum altitude
    ≤ 2000 m
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Switching threshold
    9.6 V (“0” signal)
  • Rated operating current Ie
    9 A (AC-51)
  • Load current range
    1.5 A ... 9 A (see to derating)
  • Cooling time
    20 min. (for auto reset)
  • Response time
    2 s
  • Operating voltage display
    Green LED
  • Connection method
    Push-in connection
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Rated insulation voltage
    500 V
  • Standards/regulations
    IEC 60947-1
  • FLA
    6.5 A (500 V AC)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27024000
  • ECLASS 6.0
    27024000
  • ETIM 2.0
    EC001037
  • ETIM 6.0
    EC001037
  • UNSPSC 18.0
    25173902
  • Width
    22.5 mm
  • Degree of protection
    IP20
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Input name
    Control input
  • Output name
    Acknowledge output
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10A
  • Operate threshold
    > 45 A
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Maximum power dissipation
    14.6 W
  • Indication
    Red LED
  • Connection name
    Load circuit
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • Designation
    Category (ISO 13849)
  • Identification
    ≤ 3
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27370905
  • ECLASS 7.0
    27024002
  • ETIM 4.0
    EC001037
  • UNSPSC 6.01
    30211915
  • UNSPSC 7.0901
    39121514
  • UNSPSC 20.0
    25173902
  • Note
    Confirmation: floating change-over contact, signal contact
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Rated actuating voltage UC
    24 V DC
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Operating voltage range
    42 V AC ... 550 V AC
  • Leakage current
    0 mA
  • Switching capacity according to IEC 60947-5-1
    3 A (230 V, AC15)
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Operating mode
    100% operating factor
  • Assembly instructions
    alignable, for spacing see derating
  • Minimum power dissipation
    1.1 W
  • Conductor cross section AWG
    24 ... 14
  • Overvoltage category
    III
  • Certificate
    NLDX.E228652
  • SCCR
    100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • ECLASS 10.0.1
    27370905
  • ECLASS 4.1
    27021100
  • ECLASS 5.0
    27024000
  • ETIM 7.0
    EC001037
  • UNSPSC 11
    39121514
  • UNSPSC 19.0
    25173902
  • Height
    107.5 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Rated control supply current IS
    40 mA
  • Typical turn-off time
    < 30 ms
  • Type of note
    Notes on operation
  • Ambient temperature (operation)
    -25 °C ... 70 °C (observe derating)
  • Type of protection
    Surge protection
  • Rated actuating current IC
    5 mA (Input type 1)
  • Rated operating voltage Ue
    500 V AC
  • Mains frequency
    50/60 Hz
  • Contact type
    1 changeover contact
  • Motor starter type
    Direct starter
  • Mounting type
    DIN rail mounting
  • Status display
    Yellow LED
  • Stripping length
    10 mm
  • Rated surge voltage
    6 kV
  • Degree of pollution
    2
  • Additional text
    Safe shutdown
  • Category code
    NLDX
  • Group installation
    20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
  • ECLASS 4.0
    27021100
  • ECLASS 9.0
    27370905
  • ETIM 3.0
    EC001037
  • UNSPSC 12.01
    39121514
  • UNSPSC 13.2
    25173902
  • UNSPSC 21.0
    25173902

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?