Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 48 V DC/10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903160 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Connection in parallel Yes, for redundancy and increased capacity
- Output power 480 W
- Peak switching voltages nominal load < 1000 mVPP
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid max. 1.5 mm²
- Stripping length 8 mm
- Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Electrostatic discharge EN 61000-4-2
- Frequency range 0.15 MHz ... 80 MHz
- Conducted interference EN 61000-4-6
- ECLASS 11.0 27040701
- ECLASS 9.0 27040701
- UNSPSC 20.0 39121004
- Width 68 mm
- Depth 160 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (start-up type tested) -40 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Current consumption 5.6 A (100 V AC)
- Mains buffering time typ. 10 ms (120 V AC)
- Power factor (cos phi) 0.85
- Nominal output current (IN) 10 A
- Connection in series yes
- Typical response time < 1 s
- Installation distance top/bottom 50 mm / 50 mm
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Dielectric strength maximum ≤ 300 V AC 15 s
- Discharge current to PE < 3.5 mA
- Inrush current 20 A (at 25 °C)
- Input fuse 10 A (internal (device protection))
- Dynamic Boost (IDyn.Boost) 15 A (5 s)
- Feedback voltage resistance ≤ 60 V DC
- Maximum power dissipation in no-load condition < 5.7 W (230 V)
- Insulation voltage input/output 3 kV AC
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 24
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Contact discharge 6 kV (Test Level 4)
- Test field strength 10 V/m (Test Level 3)
- Surge voltage load (surge) EN 61000-4-5
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27040701
- ECLASS 4.1 27040702
- ETIM 4.0 EC002540
- ETIM 7.0 EC002540
- UNSPSC 21.0 39121004
- Height 130 mm
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Nominal input voltage range 100 V AC ... 240 V AC
- Nominal power consumption 604.7 VA
- Protective circuit/component Varistor
- Setting range of the output voltage (USet) 36 V DC ... 55 V DC (> 48 V DC, constant capacity restricted)
- Derating > 60 °C ... 70 °C (2.5%/K)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Net weight 1.4 kg
- Protection class I (in closed control cabinet)
- Connection method Push-in connection
- EMC requirements for noise immunity EN 61000-6-1
- Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
- Rail applications EN 50121-4
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Discharge in air 8 kV (Test Level 4)
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- I/O/S asymmetrical
- REACh SVHC Lead 7439-92-1
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.1 27049002
- ETIM 6.0 EC002540
- UNSPSC 13.2 39121004
- UNSPSC 19.0 39121004
- Installation height ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- AC frequency range 50 Hz ... 60 Hz ±10 %
- Recommended breaker for input protection 10 A ... 16 A (Characteristics B, C, D, K)
- Type of protection Transient surge protection
- Nominal output voltage 48 V DC ±1 %
- Protection against overvoltage at the output (OVP) ≤ 60 V DC
- Residual ripple < 50 mVPP (with nominal values)
- Power loss nominal load max. < 44 W
- MTBF (IEC 61709, SN 29500) > 1800000 h (25 °C)
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 16
- EMC requirements for noise emission EN 61000-6-3
- Standard - Safe isolation DIN VDE 0100-410
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Input 3 kV (Test Level 3 - symmetrical)
- Voltage 10 V (Test Level 3)
- ECLASS 5.0 27049002
- ECLASS 7.0 27049002
- Efficiency > 93 % (for 230 V AC and nominal values)
- Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
- Conductor cross section flexible max. 1.5 mm²
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- UL approvals UL Listed UL 508
- Electromagnetic HF field EN 61000-4-3
- Fast transients (burst) EN 61000-4-4
- Output 1 kV (Test Level 2 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.0 27040702
- ECLASS 6.0 27049000
- UNSPSC 18.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?