Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 12 V DC/10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903158 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 35 mm
- Installation distance right/left 0 mm / 0 mm
- Degree of protection IP20
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Degree of pollution 2
- Nominal input voltage range 100 V AC ... 240 V AC
- Dielectric strength maximum ≤ 300 V AC 15 s
- Nominal power consumption 254.7 VA
- Input fuse 6.3 A Fast blow (internal (device protection))
- Type of protection Transient surge protection
- Nominal output voltage 12 V DC ±1 %
- Connection in parallel Yes, for redundancy and increased capacity
- Protection against overvoltage at the output (OVP) ≤ 22 V DC
- Residual ripple < 50 mVPP (with nominal values)
- Height 130 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (start-up type tested) -25 °C
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Discharge current to PE < 0.25 mA
- Inrush current ≤ 30 A (typical)
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Protective circuit/component Varistor
- Setting range of the output voltage (USet) 12 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
- Dynamic Boost (IDyn.Boost) 15 A (5 s)
- Feedback voltage resistance < 25 V
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Typical response time < 1 s
- Net weight 0.4 kg
- Efficiency typ. 87.5 % (120 V AC)
- MTBF (IEC 61709, SN 29500) > (25 °C)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section AWG min. 24
- Conductor cross section AWG max. 16
- Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
- Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Rail applications EN 50121-4
- UL approvals UL Listed UL 508
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Depth 115 mm
- Installation distance top/bottom 50 mm / 50 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Installation height ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
- AC frequency range 50 Hz ... 60 Hz ±10 %
- Current consumption 2.2 A (100 V AC)
- Mains buffering time typ. 20 ms (120 V AC)
- Power factor (cos phi) 0.53
- Nominal output current (IN) 10 A
- Derating > 60 °C ... 70 °C (2.5%/K)
- Connection in series yes
- Output power 120 W
- Maximum power dissipation in no-load condition < 1 W (230 V)
- Power loss nominal load max. < 15 W (230 V)
- Insulation voltage input/output 3 kV AC (type test)
- Protection class II (in closed control cabinet)
- Housing material PC
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 8 mm
- EMC requirements for noise immunity EN 61000-6-1
- EMC requirements for noise emission EN 61000-6-3
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Standard - Safe isolation DIN VDE 0100-410
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Electrostatic discharge EN 61000-4-2
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 6 kV (Test Level 3)
- Test field strength 10 V/m (Test Level 3)
- Comments Criterion A
- Fast transients (burst) EN 61000-4-4
- Surge voltage load (surge) EN 61000-4-5
- Conducted interference EN 61000-4-6
- Voltage 230 V AC
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- REACh SVHC Lead 7439-92-1
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.1 27040702
- ECLASS 5.0 27049002
- ECLASS 5.1 27049002
- ETIM 4.0 EC002540
- ETIM 6.0 EC002540
- UNSPSC 13.2 39121004
- UNSPSC 19.0 39121004
- UNSPSC 20.0 39121004
- Discharge in air 8 kV (Test Level 3)
- Electromagnetic HF field EN 61000-4-3
- Frequency range 0.15 MHz ... 80 MHz
- Input 3 kV (Test Level 4 - symmetrical)
- Output 1 kV (Test Level 3 - symmetrical)
- Signal 1 kV (Test Level 2 - asymmetrical)
- Voltage dips EN 61000-4-11
- Frequency 50 Hz
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27040701
- ECLASS 11.0 27040701
- ECLASS 4.0 27040702
- ECLASS 6.0 27049000
- ECLASS 7.0 27049002
- ECLASS 9.0 27040701
- ETIM 7.0 EC002540
- UNSPSC 18.0 39121004
- UNSPSC 21.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?