2903157 Phoenix Contact AC/DC Power Supplies
Part#:2903157
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 12Â VÂ DC/5Â A C2LPS
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903157 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Degree of protection IP20
- Degree of pollution 2
- Nominal power consumption 137.3 VA
- Type of protection Transient surge protection
- Connection in parallel Yes, for redundancy and increased capacity
- Power loss nominal load max. < 10 W (230 V)
- Housing material PC
- Conductor cross section flexible max. 1.5 mm²
- UL approvals UL Listed ULÂ 508
- Electromagnetic HF field ENÂ 61000-4-3
- Surge voltage load (surge) ENÂ 61000-4-5
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27040701
- ECLASS 10.0.1 27040701
- ECLASS 6.0 27049000
- ETIM 4.0 EC002540
- ECLASS 9.0 27040701
- UNSPSC 21.0 39121004
- Depth 115 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Dielectric strength maximum ≤ 300 V AC 15 s
- Current consumption 1.1 A (100Â VÂ AC)
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Setting range of the output voltage (USet) 12 VÂ DC ... 18 VÂ DC (> 12 VÂ DC, constant capacity restricted)
- Feedback voltage resistance < 25 V
- Output power 60 W
- Efficiency > 86 % (for 230 V AC and nominal values)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid max. 1.5 mm²
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard - Electrical safety IECÂ 60950-1/VDEÂ 0805 (SELV)
- Rail applications ENÂ 50121-4
- Discharge in air 8 kV (Test Level 3)
- Test field strength 10 V/m (Test Level 3)
- Fast transients (burst) ENÂ 61000-4-4
- Height 130 mm
- Installation distance top/bottom 50 mm / 50 mm
- Ambient temperature (start-up type tested) -25 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Discharge current to PE < 0.25 mA
- Mains buffering time typ. 20 ms (120Â VÂ AC)
- Power factor (cos phi) 0.51
- Nominal output current (IN) 5 A
- Connection in series yes
- Width 30 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Nominal input voltage range 100 VÂ AC ... 240 VÂ AC
- Inrush current ≤ 25 A (typical)
- Protective circuit/component Varistor
- Protection against overvoltage at the output (OVP) ≤ 22 V DC
- Net weight 0.32 kg
- Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
- Conductor cross section AWG max. 16
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Comments Criterion A
- Conducted interference ENÂ 61000-4-6
- REACh SVHC Lead 7439-92-1
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.0 27040702
- ECLASS 5.1 27049002
- ETIM 7.0 EC002540
- UNSPSC 13.2 39121004
- UNSPSC 19.0 39121004
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Installation height ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
- AC frequency range 50 Hz ... 60 Hz ±10 %
- Input fuse 6.3 A Slow-blow
- Nominal output voltage 12 V DC ±1 %
- Derating > 60 °C ... 70 °C (2.5%/K)
- Residual ripple < 50 mVPP (with nominal values)
- Maximum power dissipation in no-load condition < 1 W (230 V)
- Insulation voltage input/output 3 kV AC (type test)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 24
- EMC requirements for noise emission ENÂ 61000-6-3
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 6 kV (Test Level 3)
- Input 3 kV (Test Level 4 - symmetrical)
- Signal 1 kV (Test Level 2 - asymmetrical)
- Voltage dips ENÂ 61000-4-11
- Frequency 50 Hz
- ECLASS 5.0 27049002
- ECLASS 4.1 27040702
- ECLASS 7.0 27049002
- ETIM 6.0 EC002540
- UNSPSC 18.0 39121004
- UNSPSC 20.0 39121004
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Typical response time < 1 s
- MTBF (IEC 61709, SN 29500) 25 °C
- Protection class II (in closed control cabinet)
- Connection method Push-in connection
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 8 mm
- Standard - Safety of transformers ENÂ 61558-2-16 (air clearances and creepage distances only)
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Electrostatic discharge EN 61000-4-2
- Frequency range 0.15 MHz ... 80 MHz
- Output 1 kV (Test Level 3 - symmetrical)
- Voltage 230 VÂ AC
- Criterion A Normal operating behavior within the specified limits.
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?