Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 3-phase, output: 24 V DC/10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903154 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 160 mm
- Degree of protection IP20
- Nominal input voltage range 3x 400 V AC ... 500 V AC
- Discharge current to PE < 3.5 mA
- Input fuse 3.15 A (internal (device protection), slow-blow)
- Protective circuit/component Varistor
- Derating > 60 °C ... 70 °C (2.5%/K)
- Connection in parallel Yes, for redundancy and increased capacity
- Power loss nominal load max. < 22 W (480 V AC)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Electrostatic discharge EN 61000-4-2
- Frequency range 0.15 MHz ... 80 MHz
- Surge voltage load (surge) EN 61000-4-5
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 10.0.1 27040701
- ECLASS 6.0 27049000
- ETIM 4.0 EC002540
- UNSPSC 19.0 39121004
- Width 42 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (start-up type tested) -40 °C
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal power consumption 451.7 VA
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Maximum power dissipation in no-load condition < 1.1 W (400 V AC)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section AWG min. 24
- Stripping length 8 mm
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic HF field EN 61000-4-3
- Contact discharge 6 kV (Test Level 4)
- Signal 1 kV (Test Level 1 - symmetrical)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.0 27040700
- ECLASS 9.0 27040701
- UNSPSC 18.0 39121004
- UNSPSC 21.0 39121004
- Installation distance top/bottom 50 mm / 50 mm
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 3x 400 V AC ... 500 V AC -20 % ....+15 %
- Mains buffering time typ. 10 ms (400 V AC)
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
- Connection in series yes
- Typical response time < 1 s
- Efficiency > 92 % (at 400 V AC and nominal values)
- Insulation voltage input/output 3 kV AC (type test)
- Conductor cross section flexible max. 1.5 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Standard - Safe isolation DIN VDE 0100-410
- Conducted noise emission EN 55016
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Input 3 kV (Test Level 3 - symmetrical)
- Voltage 10 V (Test Level 3)
- ECLASS 11.0 27040701
- ECLASS 5.1 27049000
- ETIM 6.0 EC002540
- UNSPSC 13.2 39121004
- UNSPSC 20.0 39121004
- Height 130 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Degree of pollution 2
- AC frequency range 50 Hz ... 60 Hz
- Current consumption 3x 0.6 A (400 V AC)
- Power factor (cos phi) 0.58
- Type of protection Transient surge protection
- Dynamic Boost (IDyn.Boost) 15 A (5 s)
- Nominal output current (IN) 10 A
- Output power 240 W
- Net weight 0.9 kg
- Protection class I (in closed control cabinet)
- Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
- Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
- Rail applications EN 50121-4
- UL approvals UL Listed UL 508
- Test field strength 10 V/m (Test Level 3)
- Output 1 kV (Test Level 2 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 5.0 27049000
- ECLASS 7.0 27049002
- ETIM 7.0 EC002540
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Installation height ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
- Inrush current ≤ 26 A (typical)
- Nominal output voltage 24 V DC ±1 %
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- Residual ripple ≤ 20 mVPP
- MTBF (IEC 61709, SN 29500) > 2100000 h (25 °C)
- Connection method Push-in connection
- Conductor cross section AWG max. 16
- EMC requirements for noise emission EN 61000-6-3
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Discharge in air 8 kV (Test Level 4)
- Comments Criterion A
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27040700
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?