2903153 Phoenix Contact AC/DC Power Supplies
Part#:2903153
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 3-phase, output: 24 V DC/5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903153 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 115 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Installation height ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
- Input fuse 3.15 A (internal (device protection), slow-blow)
- Protective circuit/component Varistor
- Width 35 mm
- Installation distance right/left 0 mm / 0 mm
- Height 130 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 3x 400 V AC ... 500 V AC -20 % ....+15 %
- AC frequency range 50 Hz ... 60 Hz
- Inrush current ≤ 22 A (typical)
- Nominal output voltage 24 V DC ±1 %
- Nominal output current (IN) 5 A
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Maximum power dissipation in no-load condition < 1 W (400 V AC)
- Insulation voltage input/output 3 kV AC (type test)
- Conductor cross section flexible min. 0.2 mm²
- EMC requirements for noise emission EN 61000-6-3
- Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 6 kV (Test Level 4)
- Frequency range 0.15 MHz ... 80 MHz
- Input 3 kV (Test Level 3 - symmetrical)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.0 27040700
- ETIM 4.0 EC002540
- UNSPSC 13.2 39121004
- Installation distance top/bottom 50 mm / 50 mm
- Climatic class 3K3 (in acc. with EN 60721)
- Nominal input voltage range 3x 400 V AC ... 500 V AC
- Nominal power consumption 243.6 VA
- Power factor (cos phi) 0.55
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
- Derating > 60 °C ... 70 °C (2.5%/K)
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- Typical response time < 1 s
- Efficiency > 91 % (at 400 V AC and nominal values)
- Conductor cross section solid max. 1.5 mm²
- Stripping length 8 mm
- EMC requirements for noise immunity EN 61000-6-1
- UL approvals UL Listed UL 508
- Electrostatic discharge EN 61000-4-2
- Comments Criterion A
- Output 1 kV (Test Level 2 - symmetrical)
- ECLASS 11.0 27040701
- ECLASS 7.0 27049002
- ETIM 6.0 EC002540
- UNSPSC 18.0 39121004
- UNSPSC 21.0 39121004
- Degree of protection IP20
- Ambient temperature (start-up type tested) -25 °C
- Degree of pollution 2
- Current consumption 3x 0.4 A (400 V AC)
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Dynamic Boost (IDyn.Boost) 7.5 A (5 s)
- Output power 120 W
- Power loss nominal load max. < 12 W (480 V AC)
- Connection method Push-in connection
- Conductor cross section solid min. 0.2 mm²
- Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
- Rail applications EN 50121-4
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electromagnetic HF field EN 61000-4-3
- Surge voltage load (surge) EN 61000-4-5
- Criterion A Normal operating behavior within the specified limits.
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27040700
- ECLASS 6.0 27049000
- UNSPSC 20.0 39121004
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Discharge current to PE < 0.25 mA
- Mains buffering time typ. 20 ms (400 V AC)
- Type of protection Transient surge protection
- Connection in series yes
- Connection in parallel Yes, for redundancy and increased capacity
- MTBF (IEC 61709, SN 29500) > 2300000 h (25 °C)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section AWG min. 24
- Conductor cross section AWG max. 16
- Standard - Safe isolation DIN VDE 0100-410
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Discharge in air 8 kV (Test Level 4)
- Test field strength 10 V/m (Test Level 3)
- Signal 1 kV (Test Level 1 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 5.1 27049000
- ETIM 7.0 EC002540
- UNSPSC 19.0 39121004
- Residual ripple ≤ 20 mVPP
- Net weight 0.4 kg
- Protection class II (in closed control cabinet)
- Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
- Conductor cross section flexible max. 1.5 mm²
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Conducted noise emission EN 55016
- Fast transients (burst) EN 61000-4-4
- Voltage 10 V (Test Level 3)
- Conducted interference EN 61000-4-6
- ECLASS 10.0.1 27040701
- ECLASS 5.0 27049000
- ECLASS 9.0 27040701
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.