2903149 Phoenix Contact AC/DC Power Supplies
Part#:2903149
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 24 V DC/10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903149 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 130 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 100 V AC ... 240 V AC
- Dielectric strength maximum 300 V AC 15 s
- Width 42 mm
- Degree of protection IP20
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Discharge current to PE < 3.5 mA
- Nominal power consumption 285 VA
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Protective circuit/component Varistor
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (constant capacity)
- Installation distance top/bottom 50 mm / 50 mm
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (start-up type tested) -25 °C
- Installation height ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
- AC frequency range 50 Hz ... 60 Hz ±10 %
- Current consumption 3.1 A (100 V AC)
- Power factor (cos phi) 0.93
- Nominal output current (IN) 10 A
- Feedback voltage resistance ≤ 35 V DC
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Efficiency > 91 % (for 230 V AC and nominal values)
- MTBF (IEC 61709, SN 29500) > 1800000 h (25 °C)
- Connection method Push-in connection
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 1.5 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Standard - Safe isolation DIN VDE 0100-410
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Rail applications EN 50121-4
- Discharge in air 8 kV (Test Level 4)
- Electromagnetic HF field EN 61000-4-3
- Frequency range 0.15 MHz ... 80 MHz
- Signal 1 kV (Test Level 2 - asymmetrical)
- Criterion A Normal operating behavior within the specified limits.
- Surge voltage load (surge) EN 61000-4-5
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.0 27040700
- ECLASS 6.0 27049000
- ECLASS 7.0 27049002
- ETIM 6.0 EC002540
- UNSPSC 18.0 39121004
- Depth 160 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Mains buffering time typ. 15 ms (120 V AC)
- Type of protection Transient surge protection
- Derating > 60 °C ... 70 °C (2.5%/K)
- Connection in series yes
- Residual ripple < 10 mVPP (with nominal values)
- Net weight 1 kg
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 8 mm
- EMC requirements for noise emission EN 61000-6-3
- Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
- UL approvals UL Listed UL 508
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electrostatic discharge EN 61000-4-2
- Contact discharge 6 kV (Test Level 4)
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- Voltage 10 V (Test Level 3)
- ECLASS 10.0.1 27040701
- ECLASS 4.1 27040700
- ECLASS 5.0 27049000
- ETIM 4.0 EC002540
- UNSPSC 13.2 39121004
- UNSPSC 19.0 39121004
- UNSPSC 21.0 39121004
- Inrush current ≤ 25 A (typical)
- Input fuse 6.3 A (internal (device protection))
- Nominal output voltage 24 V DC ±1 %
- Dynamic Boost (IDyn.Boost) 15 A (5 s)
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- Output power 240 W
- Power loss nominal load max. < 25 W
- Maximum power dissipation in no-load condition < 5.1 W (230 V)
- Protection class I (in closed control cabinet)
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section AWG min. 24
- Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Test field strength 10 V/m (Test Level 3)
- Comments Criterion A
- Input 3 kV (Test Level 3 - symmetrical)
- Output 1 kV (Test Level 2 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27040701
- ECLASS 5.1 27049000
- ECLASS 9.0 27040701
- ETIM 7.0 EC002540
- UNSPSC 20.0 39121004
- Connection in parallel Yes, for redundancy and increased capacity
- Typical response time < 1 s
- Insulation voltage input/output 3 kV AC (type test)
- Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
- Conductor cross section AWG max. 16
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?