Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/55 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903001 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Nominal input voltage range 100 V AC ... 240 V AC
- Input fuse 3.15 A (slow-blow, internal)
- Inrush current < 25 A (typical)
- Protective circuit/component Varistor
- Derating 55 °C ... 70 °C (2.5%/K)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Power loss nominal load max. < 7 W
- MTBF (IEC 61709, SN 29500) > 647000 h (40 °C)
- Foot latch material POM (Polyoxymethylen)
- Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
- Conductor cross section AWG min. 24
- EMC requirements for noise emission EN 61000-6-3
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Frequency range 10 kHz ... 80 MHz
- Voltage 10 V (Test Level 3)
- ECLASS 11.0 27040701
- ECLASS 4.1 27040700
- ECLASS 6.0 27049000
- ETIM 7.0 EC002540
- UNSPSC 12.01 39121004
- Height 90 mm
- Installation distance top/bottom 30 mm / 30 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Nominal output voltage 15 V DC ±1 %
- Feedback voltage resistance < 25 V DC
- Typical response time < 1 s
- Net weight 0.21 kg
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid max. 2.5 mm²
- Stripping length 8 mm
- Standard - Safe isolation DIN VDE 0100-410
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 6 kV (Test Level 3)
- Input 2 kV (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 5.1 27049000
- ETIM 6.0 EC002540
- UNSPSC 6.01 30211502
- UNSPSC 20.0 39121004
- Width 35 mm
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Current consumption 1.3 A (100 V AC)
- Type of protection Transient surge protection
- Connection in series yes
- Residual ripple < 50 mVPP (with nominal values)
- Protection class II (in closed control cabinet)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 2.5 mm²
- Screw thread M3
- EMC requirements for noise immunity EN 61000-6-1
- Mains variation/undervoltage EN 61000-4-11
- Electrostatic discharge EN 61000-4-2
- Comments Criterion A
- Surge voltage load (surge) EN 61000-4-5
- ECLASS 10.0.1 27040701
- ECLASS 5.0 27049000
- ETIM 4.0 EC000599
- UNSPSC 7.0901 39121004
- UNSPSC 18.0 39121004
- UNSPSC 21.0 39121004
- Depth 84 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Climatic class 3K3 (in acc. with EN 60721)
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Mains buffering time > 25 ms (120 V AC)
- Nominal output current (IN) 3.7 A (-25 °C ... 55 °C)
- Output power 55 W
- Efficiency typ. 87 % (120 V AC)
- Connection method Screw connection
- Conductor cross section AWG max. 14
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- UL approvals UL/C-UL listed UL 508
- Electromagnetic HF field EN 61000-4-3
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.0 27040700
- ECLASS 9.0 27040701
- UNSPSC 11 39121004
- UNSPSC 13.2 39121004
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Input voltage range 85 V AC ... 264 V AC
- Nominal power consumption 127.6 VA
- Power factor (cos phi) 0.49
- Connection in parallel Yes, for redundancy and increased capacity
- Protection against overvoltage at the output (OVP) ≤ 25 V DC
- Maximum power dissipation in no-load condition < 0.3 W
- Housing material Polycarbonate
- Insulation voltage input/output 4 kV AC (type test)
- Conductor cross section flexible min. 0.2 mm²
- Standard - Safety of transformers EN 61558-2-16
- Standard - Electrical safety IEC 62368-1/VDE 0805 (SELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Discharge in air 8 kV (Test Level 3)
- Test field strength 10 V/m
- Output 1 kV (Test Level 2 - symmetrical)
- Voltage dips EN 61000-4-11
- China RoHS Environmentally Friendly Use Period = 25;
- ETIM 3.0 EC001039
- ECLASS 7.0 27049002
- UNSPSC 19.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?