2903000 Phoenix Contact AC/DC Power Supplies
Part#:2903000
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/30 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903000 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Degree of pollution 2
- Nominal input voltage range 100 VÂ AC ... 240 VÂ AC
- Power factor (cos phi) 0.49
- Nominal output current (IN) 2 A (-25 °C ... 55 °C)
- Connection in series yes
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- MTBF (IEC 61709, SN 29500) > 911000 h (40 °C)
- Housing material Polycarbonate
- Assembly instructions alignable: 0Â mm horizontally, 30Â mm vertically
- Conductor cross section flexible max. 2.5 mm²
- Standard - Safety of transformers ENÂ 61558-2-16
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Discharge in air 8 kV (Test Level 3)
- Input 2 kV (Test Level 3 - symmetrical)
- Voltage dips ENÂ 61000-4-11
- Installation distance top/bottom 30 mm / 30 mm
- Climatic class 3K3 (in acc. with EN 60721)
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Inrush current < 30 A (typical)
- Nominal output voltage 15 V DC ±1 %
- Connection in parallel Yes, for redundancy and increased capacity
- Output power 30 W
- Net weight 0.15 kg
- Connection method Screw connection
- Conductor cross section AWG min. 24
- Standard - Electrical safety IECÂ 62368-1/VDEÂ 0805 (SELV)
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electrostatic discharge EN 61000-4-2
- Contact discharge 6 kV (Test Level 3)
- Comments Criterion A
- Test field strength 10 V/m
- China RoHS Environmentally Friendly Use Period = 25;
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ETIM 6.0 EC002540
- UNSPSC 12.01 39121004
- UNSPSC 21.0 39121004
- Depth 84 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal power consumption 70.8 VA
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Derating 55 °C ... 70 °C (2.5%/K)
- Feedback voltage resistance < 25 VÂ DC
- Typical response time < 1 s
- Efficiency typ. 85 % (120Â VÂ AC)
- Foot latch material POM (Polyoxymethylen)
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 14
- Screw thread M3
- Mains variation/undervoltage ENÂ 61000-4-11
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Fast transients (burst) ENÂ 61000-4-4
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 11.0 27040701
- ECLASS 6.0 27049000
- ECLASS 9.0 27040701
- ETIM 3.0 EC001039
- UNSPSC 13.2 39121004
- Width 22.5 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 85 VÂ AC ... 264 VÂ AC
- Mains buffering time > 20 ms (120Â VÂ AC)
- Protective circuit/component Varistor
- Residual ripple < 40 mVPP (with nominal values)
- Power loss nominal load max. < 4.6 W
- Insulation voltage input/output 4 kV AC (type test)
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- UL approvals UL/C-UL listed UL 508
- Electromagnetic HF field ENÂ 61000-4-3
- Surge voltage load (surge) ENÂ 61000-4-5
- Output 1 kV (Test Level 2 - symmetrical)
- Conducted interference ENÂ 61000-4-6
- ECLASS 4.0 27040700
- ETIM 7.0 EC002540
- UNSPSC 6.01 30211502
- UNSPSC 7.0901 39121004
- Height 90 mm
- Degree of protection IP20
- Current consumption 0.8 A (100Â VÂ AC)
- Input fuse 2 A (slow-blow, internal)
- Type of protection Transient surge protection
- Protection against overvoltage at the output (OVP) ≤ 25 V DC
- Maximum power dissipation in no-load condition < 0.3 W
- Protection class II (in closed control cabinet)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid max. 2.5 mm²
- EMC requirements for noise immunity ENÂ 61000-6-1
- EMC requirements for noise emission ENÂ 61000-6-3
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Frequency range 10 kHz ... 80 MHz
- Voltage 10 V (Test Level 3)
- ECLASS 4.1 27040700
- ECLASS 5.0 27049000
- ETIM 4.0 EC000599
- UNSPSC 18.0 39121004
- UNSPSC 19.0 39121004
- ECLASS 10.0.1 27040701
- ECLASS 5.1 27049000
- ECLASS 7.0 27049002
- UNSPSC 11 39121004
- UNSPSC 20.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.