Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/55 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902999 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Mains buffering time > 20 ms (120 V AC)
- Protective circuit/component Varistor
- Protection against overvoltage at the output (OVP) ≤ 25 V DC
- Connection in parallel Yes, for redundancy and increased capacity
- Net weight 0.2 kg
- ECLASS 5.0 27049000
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Climatic class 3K3 (in acc. with EN 60721)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 100 V AC ... 240 V AC
- Inrush current < 30 A (typical)
- Nominal output voltage 12 V DC ±1 %
- Connection in series yes
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- MTBF (IEC 61709, SN 29500) > 865000 h (40 °C)
- Housing material Polycarbonate
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- Standard - Electrical safety IEC 62368-1/VDE 0805 (SELV)
- Mains variation/undervoltage EN 61000-4-11
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Degree of pollution 2
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Nominal power consumption 127 VA
- Power factor (cos phi) 0.49
- Feedback voltage resistance < 25 V DC
- Power loss nominal load max. < 8 W
- Protection class II (in closed control cabinet)
- Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
- Conductor cross section flexible max. 2.5 mm²
- Screw thread M3
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Contact discharge 6 kV (Test Level 3)
- Comments Criterion A
- Surge voltage load (surge) EN 61000-4-5
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.0 27040700
- Input voltage range 85 V AC ... 264 V AC
- Current consumption 1.3 A (100 V AC)
- Type of protection Transient surge protection
- Input fuse 2 A (slow-blow, internal)
- Test field strength 10 V/m
- AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Nominal output current (IN) 4.6 A (-25 °C ... 55 °C)
- Residual ripple < 30 mVPP (with nominal values)
- Output power 55 W
- Conductor cross section flexible min. 0.2 mm²
- Foot latch material POM (Polyoxymethylen)
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- UL approvals UL/C-UL listed UL 508
- Discharge in air 8 kV (Test Level 3)
- Output 1 kV (Test Level 2 - symmetrical)
- Voltage 10 V (Test Level 3)
- ECLASS 10.0.1 27040701
- ECLASS 5.1 27049000
- Width 35 mm
- Installation distance right/left 0 mm / 0 mm
- Typical response time < 1 s
- Standard - Safe isolation DIN VDE 0100-410
- Electromagnetic HF field EN 61000-4-3
- Frequency range 150 kHz ... 80 MHz
- Voltage dips EN 61000-4-11
- China RoHS Environmentally Friendly Use Period = 25;
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 7.0 27049002
- ETIM 6.0 EC002540
- ETIM 3.0 EC001039
- Depth 84 mm
- Installation distance top/bottom 30 mm / 30 mm
- Maximum power dissipation in no-load condition < 0.3 W
- Connection method Screw connection
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- ECLASS 6.0 27049000
- ETIM 7.0 EC002540
- UNSPSC 6.01 30211502
- UNSPSC 12.01 39121004
- UNSPSC 21.0 39121004
- Ambient temperature (start-up type tested) -25 °C
- Derating 55 °C ... 70 °C (2.5%/K)
- Conductor cross section solid max. 2.5 mm²
- EMC requirements for noise emission EN 61000-6-3
- Standard - Safety of transformers EN 61558-2-16
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Electrostatic discharge EN 61000-4-2
- ECLASS 9.0 27040701
- UNSPSC 11 39121004
- UNSPSC 19.0 39121004
- UNSPSC 18.0 39121004
- Height 90 mm
- Efficiency typ. 87 % (120 V AC)
- Insulation voltage input/output 4 kV AC (type test)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section AWG max. 14
- Conductor cross section AWG min. 24
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Input 2 kV (Test Level 3 - symmetrical)
- ECLASS 11.0 27040701
- ECLASS 4.1 27040700
- ETIM 4.0 EC000599
- UNSPSC 7.0901 39121004
- UNSPSC 13.2 39121004
- UNSPSC 20.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?