Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/100 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902997 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 90 mm
- Ambient temperature (start-up type tested) -25 °C
- Input voltage range 85 VÂ AC ... 264 VÂ AC
- Inrush current < 30 A (typical)
- Protective circuit/component Varistor
- Derating 55 °C ... 70 °C (2.5%/K)
- Residual ripple < 75 mVPP (with nominal values)
- Power loss nominal load max. < 12 W
- Insulation voltage input/output 4 kV AC (type test)
- Foot latch material POM (Polyoxymethylen)
- Conductor cross section flexible max. 2.5 mm²
- Standard - Safety of transformers ENÂ 61558-2-16
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- ETIM 4.0 EC000599
- Width 55 mm
- Degree of protection IP20
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 100 VÂ AC ... 240 VÂ AC
- AC frequency range 50 Hz ... 60 Hz -10Â % ... +10Â %
- Input fuse 4 A (slow-blow, internal)
- Type of protection Transient surge protection
- Feedback voltage resistance < 25 VÂ DC
- Output power 100 W
- Efficiency typ. 88 % (120Â VÂ AC)
- Assembly instructions alignable: 0Â mm horizontally, 30Â mm vertically
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 8 mm
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Fast transients (burst) ENÂ 61000-4-4
- Test field strength 10 V/m
- Voltage dips ENÂ 61000-4-11
- ECLASS 4.0 27040700
- Installation distance right/left 0 mm / 0 mm
- Degree of pollution 2
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Mains buffering time > 20 ms (120Â VÂ AC)
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Nominal output current (IN) 8.3 A (-25 °C ... 55 °C)
- Connection in series yes
- Net weight 0.34 kg
- MTBF (IEC 61709, SN 29500) > 500000 h (40 °C)
- Conductor cross section solid min. 0.2 mm²
- Screw thread M3
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- UL approvals UL/C-UL listed UL 508
- Discharge in air 8 kV (Test Level 3)
- Voltage 10 V (Test Level 3)
- ECLASS 10.0.1 27040701
- ECLASS 6.0 27049000
- ETIM 3.0 EC001039
- UNSPSC 7.0901 39121004
- UNSPSC 12.01 39121004
- Depth 84 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Current consumption 2.19 A (100Â VÂ AC)
- Power factor (cos phi) 0.53
- Connection in parallel Yes, for redundancy and increased capacity
- Protection against overvoltage at the output (OVP) ≤ 25 V DC
- Maximum power dissipation in no-load condition < 0.4 W
- Housing material Polycarbonate
- Connection method Screw connection
- Conductor cross section AWG min. 24
- Standard - Electrical safety IECÂ 62368-1/VDEÂ 0805 (SELV)
- EMC requirements for noise emission ENÂ 61000-6-3
- Mains variation/undervoltage ENÂ 61000-4-11
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field ENÂ 61000-4-3
- Output 1 kV (Test Level 2 - symmetrical)
- Conducted interference ENÂ 61000-4-6
- ECLASS 11.0 27040701
- ECLASS 4.1 27040700
- ETIM 7.0 EC002540
- UNSPSC 18.0 39121004
- Installation distance top/bottom 30 mm / 30 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Climatic class 3K3 (in acc. with EN 60721)
- Nominal power consumption 210.8 VA
- Nominal output voltage 12 V DC ±1 %
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Typical response time < 1 s
- Protection class II (in closed control cabinet)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG max. 14
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Contact discharge 6 kV (Test Level 3)
- Comments Criterion A
- Input 2 kV (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 5.1 27049000
- ECLASS 9.0 27040701
- UNSPSC 11 39121004
- UNSPSC 21.0 39121004
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Frequency range 10 kHz ... 80 MHz
- Surge voltage load (surge) ENÂ 61000-4-5
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.0 27049000
- ECLASS 7.0 27049002
- ETIM 6.0 EC002540
- UNSPSC 19.0 39121004
- UNSPSC 6.01 30211502
- UNSPSC 13.2 39121004
- UNSPSC 20.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?