2902995 Phoenix Contact AC/DC Power Supplies
Part#:2902995
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 48 V DC/60 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902995 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 84 mm
- Nominal power consumption 134.7 VA
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Installation distance right/left 0 mm / 0 mm
- Degree of protection IP20
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Nominal input voltage range 100 V AC ... 240 V AC
- Current consumption 1.3 A (100 V AC)
- Power factor (cos phi) 0.5
- Connection in parallel Yes, for redundancy and increased capacity
- Typical response time < 1 s
- Insulation voltage input/output 4 kV AC (type test)
- Conductor cross section solid max. 2.5 mm²
- EMC requirements for noise emission EN 61000-6-3
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Frequency range 10 kHz ... 80 MHz
- Conducted interference EN 61000-4-6
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.0 27040700
- ETIM 6.0 EC002540
- ETIM 7.0 EC002540
- Width 35 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Input voltage range 85 V AC ... 264 V AC
- Input fuse 2 A (slow-blow, internal)
- Nominal output current (IN) 1.25 A (-25 °C ... 55 °C)
- Protection against overvoltage at the output (OVP) ≤ 60 V DC
- Output power 60 W
- Net weight 0.21 kg
- Foot latch material POM (Polyoxymethylen)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section AWG min. 24
- Stripping length 8 mm
- Standard - Safety of transformers EN 61558-2-16
- Standard - Safe isolation DIN VDE 0100-410
- Electrostatic discharge EN 61000-4-2
- Contact discharge 6 kV (Test Level 3)
- Comments Criterion A
- Voltage 10 V (Test Level 3)
- ECLASS 10.0.1 27040701
- ECLASS 5.0 27049000
- ECLASS 7.0 27049002
- UNSPSC 7.0901 39121004
- UNSPSC 21.0 39121004
- Height 90 mm
- Installation distance top/bottom 30 mm / 30 mm
- Climatic class 3K3 (in acc. with EN 60721)
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Mains buffering time > 20 ms (120 V AC)
- Type of protection Transient surge protection
- Derating 55 °C ... 70 °C (2.5%/K)
- Connection in series yes
- Power loss nominal load max. < 7 W
- Protection class II (in closed control cabinet)
- Connection method Screw connection
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible max. 2.5 mm²
- Standard - Electrical safety IEC 62368-1/VDE 0805 (SELV)
- Mains variation/undervoltage EN 61000-4-11
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Test field strength 10 V/m
- Surge voltage load (surge) EN 61000-4-5
- Criterion A Normal operating behavior within the specified limits.
- Voltage dips EN 61000-4-11
- ECLASS 4.1 27040700
- ETIM 3.0 EC001039
- UNSPSC 13.2 39121004
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Degree of pollution 2
- Inrush current < 30 A (typical)
- Protective circuit/component Varistor
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Efficiency typ. 89 % (120 V AC)
- Housing material Polycarbonate
- Conductor cross section solid min. 0.2 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Discharge in air 8 kV (Test Level 3)
- Fast transients (burst) EN 61000-4-4
- Output 1 kV (Test Level 2 - symmetrical)
- ECLASS 11.0 27040701
- ECLASS 5.1 27049000
- ETIM 4.0 EC000599
- UNSPSC 11 39121004
- UNSPSC 18.0 39121004
- Nominal output voltage 48 V DC ±1 %
- Feedback voltage resistance < 60 V DC
- Residual ripple < 35 mVPP (with nominal values)
- Maximum power dissipation in no-load condition < 0.4 W
- MTBF (IEC 61709, SN 29500) > 1138000 h (40 °C)
- Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
- Conductor cross section AWG max. 14
- Screw thread M3
- UL approvals UL/C-UL listed UL 508
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electromagnetic HF field EN 61000-4-3
- Input 2 kV (Test Level 3 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 6.0 27049000
- ECLASS 9.0 27040701
- UNSPSC 6.01 30211502
- UNSPSC 12.01 39121004
- UNSPSC 19.0 39121004
- UNSPSC 20.0 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?