2902879 Phoenix Contact Redundancy Modules
Part#:2902879
Manufacturer:Phoenix Contact
Category:Redundancy Modules
Product Lifecycle:Active
Get a quick Quote!
Active QUINT redundancy module for DIN rail mounting with ACB (Auto Current Balancing) Technology and monitoring functions, input: 24 V DC/2x 40 A, output: 24 V DC/1 x 80 A, including mounted UTA 107/30 universal DIN rail adapter
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Redundancy Modules that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902879 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Installation height 2000 m
- Height 130 mm
- Depth with alternative assembly 69 mm
- Installation distance top/bottom 50 mm / 50 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- ECLASS 6.0 27371000
- ETIM 4.0 EC000599
- UNSPSC 12.01 39121004
- Depth 125 mm
- Installation distance right/left 5 mm / 5 mm
- Degree of protection IP20
- Climatic class 3K3 (in acc. with EN 60721)
- Degree of pollution 2
- Nominal output current (IN) 80 A (Increasing power)
- Power loss nominal load max. 16 W (IOUT = 80 A)
- Protection class III
- Conductor cross section flexible max. 4 mm²
- Conductor cross section AWG max. 10
- Width 66 mm
- Height with alternative assembly 130 mm
- Ambient temperature (start-up type tested) -40 °C
- Input voltage range 18 VÂ DC ... 28 VÂ DC (SELV)
- Nominal input current 2x 40 A (-25 °C ... 60 °C)
- Derating 60 °C ... 70 °C (2.5%/K)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Efficiency > 98 %
- Conductor cross section solid min. 0.2 mm²
- Screw thread M3
- EMC requirements for noise immunity ENÂ 61000-6-1
- Electrostatic discharge EN 61000-4-2
- Contact discharge 8 kV (Test Level 4)
- Discharge in air 15 kV (Test Level 4)
- Comments Criterion A
- I/O/S asymmetrical
- ECLASS 4.1 27250300
- ECLASS 4.0 27250300
- ECLASS 7.0 27371010
- UNSPSC 11 39121004
- UNSPSC 21.0 32151504
- Width with alternative assembly 122 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal output voltage 0.2 V (< DC input)
- Connection in series No
- Net weight 0.9 kg
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section solid max. 6 mm²
- Stripping length 10 mm
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- UL approvals UL/C-UL listed UL 508
- Fast transients (burst) ENÂ 61000-4-4
- Conducted interference ENÂ 61000-4-6
- Voltage 10 V (Test Level 3)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.1 27371000
- ECLASS 9.0 27371010
- ETIM 7.0 EC002540
- UNSPSC 6.01 30211502
- UNSPSC 19.0 32151504
- UNSPSC 20.0 32151504
- Nominal input voltage range 24 VÂ DC
- Maximum input current 2x 45 A (-25°C ... 40°C)
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Connection method Screw connection
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG min. 16
- EMC requirements for noise emission ENÂ 61000-6-3
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field ENÂ 61000-4-3
- Output 1 kV (Test Level 2 - symmetrical)
- Surge voltage load (surge) ENÂ 61000-4-5
- Signal 1 kV (Test Level 2 - asymmetrical)
- REACh SVHC Lead 7439-92-1
- ECLASS 10.0.1 27371010
- ETIM 3.0 EC000599
- UNSPSC 7.0901 39121004
- UNSPSC 18.0 32151504
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Standard - Electrical safety ENÂ 60950-1/VDEÂ 0805 (SELV)
- Frequency range 0.15 MHz ... 80 MHz
- Test field strength 10 V/m (Test Level 3)
- Input 1 kV (Test Level 2 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 11.0 27371010
- ECLASS 5.0 27371000
- ETIM 6.0 EC002540
- UNSPSC 13.2 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?