2902879 Phoenix Contact Redundancy Modules

2902879 on Power Resource International
Phoenix Contact

Part#:2902879

Manufacturer:Phoenix Contact

Category:Redundancy Modules

Product Lifecycle:Active

Get a quick Quote!

Active QUINT redundancy module for DIN rail mounting with ACB (Auto Current Balancing) Technology and monitoring functions, input: 24 V DC/2x 40 A, output: 24 V DC/1 x 80 A, including mounted UTA 107/30 universal DIN rail adapter

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Redundancy Modules that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2902879 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Installation height
    2000 m
  • Height
    130 mm
  • Depth with alternative assembly
    69 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • ECLASS 6.0
    27371000
  • ETIM 4.0
    EC000599
  • UNSPSC 12.01
    39121004
  • Depth
    125 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Degree of protection
    IP20
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Degree of pollution
    2
  • Nominal output current (IN)
    80 A (Increasing power)
  • Power loss nominal load max.
    16 W (IOUT = 80 A)
  • Protection class
    III
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section AWG max.
    10
  • Width
    66 mm
  • Height with alternative assembly
    130 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Input voltage range
    18 V DC ... 28 V DC (SELV)
  • Nominal input current
    2x 40 A (-25 °C ... 60 °C)
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Efficiency
    > 98 %
  • Conductor cross section solid min.
    0.2 mm²
  • Screw thread
    M3
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Electrostatic discharge
    EN 61000-4-2
  • Contact discharge
    8 kV (Test Level 4)
  • Discharge in air
    15 kV (Test Level 4)
  • Comments
    Criterion A
  • I/O/S
    asymmetrical
  • ECLASS 4.1
    27250300
  • ECLASS 4.0
    27250300
  • ECLASS 7.0
    27371010
  • UNSPSC 11
    39121004
  • UNSPSC 21.0
    32151504
  • Width with alternative assembly
    122 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Nominal output voltage
    0.2 V (< DC input)
  • Connection in series
    No
  • Net weight
    0.9 kg
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Conductor cross section solid max.
    6 mm²
  • Stripping length
    10 mm
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • UL approvals
    UL/C-UL listed UL 508
  • Fast transients (burst)
    EN 61000-4-4
  • Conducted interference
    EN 61000-4-6
  • Voltage
    10 V (Test Level 3)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.1
    27371000
  • ECLASS 9.0
    27371010
  • ETIM 7.0
    EC002540
  • UNSPSC 6.01
    30211502
  • UNSPSC 19.0
    32151504
  • UNSPSC 20.0
    32151504
  • Nominal input voltage range
    24 V DC
  • Maximum input current
    2x 45 A (-25°C ... 40°C)
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Connection method
    Screw connection
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG min.
    16
  • EMC requirements for noise emission
    EN 61000-6-3
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Electromagnetic HF field
    EN 61000-4-3
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 10.0.1
    27371010
  • ETIM 3.0
    EC000599
  • UNSPSC 7.0901
    39121004
  • UNSPSC 18.0
    32151504
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Standard - Electrical safety
    EN 60950-1/VDE 0805 (SELV)
  • Frequency range
    0.15 MHz ... 80 MHz
  • Test field strength
    10 V/m (Test Level 3)
  • Input
    1 kV (Test Level 2 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 11.0
    27371010
  • ECLASS 5.0
    27371000
  • ETIM 6.0
    EC002540
  • UNSPSC 13.2
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?