Configurable temperature transducer for the connection of 2, 3, and 4-conductor resistance thermometers and resistance-type sensors. Can be configured via DIP switches or, with extended functionality, using the software. Screw connection, standard configu

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2902849 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Temperature
    B
  • EMC
    B
  • ECLASS 10.0.1
    27210129
  • ETIM 3.0
    EC001446
  • Height
    93.1 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Linear resistance measuring range
    0 Ω ... 4000 Ω (Minimum measuring span: 10% of the selected measuring range)
  • Connection technology
    2-, 3-, 4-conductor
  • Voltage output signal
    0 V ... 10 V
  • Max. output current
    24.6 mA
  • Load/output load voltage output
    10 kΩ
  • Power consumption
    ≤ 700 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω)
  • Connection method
    Screw connection
  • ECLASS 5.0
    27200200
  • ETIM 2.0
    EC001446
  • UNSPSC 6.01
    30211506
  • UNSPSC 7.0901
    39121008
  • UNSPSC 19.0
    41112105
  • Width
    6.2 mm
  • Depth
    101.2 mm
  • Maximum altitude
    ≤ 2000 m
  • Configurable/programmable
    Yes
  • Sensor types (RTD) that can be used
    Pt, Ni, Cu sensors
  • Number of outputs
    1
  • Max. output voltage
    approx. 12.3 V
  • Ripple
    < 20 mVPP
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Stripping length
    12 mm
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Maximum temperature coefficient
    0.01 %/K
  • Protective circuit
    Transient protection
  • Degree of pollution
    2
  • Noise emission
    EN 61000-6-4
  • Housing material
    PBT
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (operation)
    -20 °C ... 65 °C
  • Degree of protection
    IP20
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Temperature measuring range
    -200 °C ... 850 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 850°C via DIP switches)
  • Sensor input current
    approx. 200 µA
  • Current output signal
    0 mA ... 20 mA
  • Load/output load current output
    500 Ω (at 20 mA)
  • Typical current consumption
    < 27 mA (at 24 V DC)
  • Screw thread
    M3
  • Transmission error resistance thermometer
    0.1 % * 350 K / set measuring range; 0.1 % > 350 K (Pt/Ni)
  • Conductor cross section AWG
    26 ... 12
  • Status display
    LED red
  • Overvoltage category
    II
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Mounting position
    any
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Certificate
    DNV GL TAA00002R0
  • Vibration
    B
  • ECLASS 6.0
    27200200
  • ECLASS 5.1
    27200200
  • ETIM 6.0
    EC002919
  • UNSPSC 11
    39121008
  • UNSPSC 12.01
    39121008
  • UNSPSC 21.0
    41112105
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Transmission error resistance-type sensor
    2 Ω
  • Electrical isolation
    Basic insulation according to EN 61010
  • Rated insulation voltage
    50 V AC/DC
  • Test voltage, input/output/supply
    1.5 kV (50 Hz, 1 min.)
  • Color
    green
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Typical deviation from the measuring range final value
    0.02 %
  • Standards/regulations
    EN 61000-4-6
  • Humidity
    B
  • Identification
    UL 508 Listed
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27200200
  • ECLASS 4.1
    27200200
  • ECLASS 9.0
    27210129
  • ETIM 7.0
    EC002919
  • UNSPSC 13.2
    41112105
  • UNSPSC 20.0
    41112105
  • UNSPSC 18.0
    41112105
  • Designation
    Shipbuilding approval
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ETIM 4.0
    EC001446
  • ECLASS 11.0
    27210129
  • ECLASS 7.0
    27200206

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?