Short-circuit-proof hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 2.4 A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD and EM-RI adapters or power distribution b

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2902744 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Type of protection
    Surge protection
  • Switching threshold
    9.6 V (“0” signal)
  • Operating voltage range
    42 V AC ... 550 V AC
  • Cooling time
    20 min. (for auto reset)
  • Contact type
    1 changeover contact
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Minimum power dissipation
    0.88 W
  • Connection name
    Load circuit
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Rated insulation voltage
    500 V
  • Additional text
    Safe shutdown
  • SCCR
    100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27024000
  • ECLASS 9.0
    27370905
  • ETIM 7.0
    EC001037
  • UNSPSC 18.0
    25173902
  • UNSPSC 21.0
    25173902
  • Height
    160 mm
  • Degree of protection
    IP20
  • Input name
    Control input right/left
  • Rated actuating current IC
    5 mA
  • Output name
    Acknowledge output
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10A
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Status display
    Yellow LED
  • Stripping length
    8 mm
  • Conductor cross section AWG
    24 ... 14
  • Rated surge voltage
    6 kV
  • Identification
    GB/T 14048.6-2016
  • Group installation
    20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
  • Ambient temperature (operation)
    -25 °C ... 70 °C (observe derating)
  • Maximum altitude
    ≤ 2000 m
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Rated operating voltage Ue
    500 V AC
  • Leakage current
    0 mA
  • Switching capacity according to IEC 60947-5-1
    3 A (230 V, AC15)
  • Operating mode
    100% operating factor
  • Maximum power dissipation
    5.5 W
  • Operating voltage display
    Green LED
  • Connection method
    Screw connection
  • Overvoltage category
    III
  • Standards/regulations
    IEC 60947-1
  • Certificate
    2020970304000811
  • Category code
    NLDX / NRNT
  • ECLASS 11.0
    27370905
  • ECLASS 5.1
    27024000
  • ETIM 3.0
    EC001037
  • UNSPSC 6.01
    30211915
  • UNSPSC 13.2
    25173902
  • UNSPSC 20.0
    25173902
  • Width
    22.5 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Rated actuating voltage UC
    24 V DC
  • Typical turn-off time
    < 30 ms
  • Mains frequency
    50/60 Hz
  • Motor starter type
    Reversing starter
  • Assembly instructions
    alignable, for spacing see derating
  • Screw thread
    M3
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Torque
    0.5 Nm ... 0.6 Nm
  • Designation
    CCC
  • FLA
    2.4 A (500 V AC)
  • ECLASS 10.0.1
    27370905
  • ECLASS 4.1
    27021100
  • ETIM 2.0
    EC001037
  • ETIM 4.0
    EC001037
  • ETIM 6.0
    EC001037
  • UNSPSC 12.01
    39121514
  • UNSPSC 19.0
    25173902
  • Depth
    114.5 mm
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Rated control supply current IS
    40 mA
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Load current range
    180 mA ... 2.4 A (see to derating)
  • Note
    Confirmation: floating change-over contact, signal contact
  • Mounting type
    Bus bar mounting
  • Indication
    Red LED
  • Degree of pollution
    2
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27021100
  • ECLASS 6.0
    27024000
  • ECLASS 7.0
    27024002
  • UNSPSC 7.0901
    39121514
  • UNSPSC 11
    39121514

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?