2902058 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2902058
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Universally configurable frequency transducer for converting frequency and PWM signals into standard signals. Sensor voltages greater than 8.2 V DC are possible in combination with MINI MCR-2-SPS-PT 1033201. Push-in connection technology.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902058 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 119.2 mm
- Configurable/programmable Yes
- Frequency measuring range 0.002 Hz ... 200 kHz
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Available input sources NAMUR initiators
- Current output signal 0 mA ... 20 mA (via DIP switch)
- Max. output current 24.6 mA
- Step response (0–99%) < 35 ms (f > 500 Hz)
- Height 109.81 mm
- Ambient temperature (operation) -40 °C ... 70 °C
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Max. output voltage approx. 12.3 V
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Degree of protection IP20 (not assessed by UL)
- Frequency input Frequency input
- Load/output load current output ≤ 600 Ω (at 20 mA)
- Contact type 1 N/O contact
- REACh SVHC Lead 7439-92-1
- Width 6.2 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Number of outputs 1
- Voltage output signal 0 V ... 10 V (via DIP switch)
- Ripple < 20 mVPP (at 600 Ω)
- Nominal supply voltage 24 V DC
- Load/output load voltage output ≥ 10 kΩ
- Maximum switching voltage 30 V DC
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Maximum temperature coefficient 0.01 %/K
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- Standards/regulations EN 61000-4-6
- Maximum transmission error 0.1 % (Frequency)
- Degree of pollution 2
- Electromagnetic compatibility Conformance with EMC directive
- Mounting position any
- Color gray
- Typical deviation from the measuring range final value 2.8 %
- UL, USA/Canada UL 508 Listed
- EMC A
- Min. switching current 100 µA
- Conductor cross section solid 0.2 mm² ... 2.5 mm² (with ferrule)
- Overvoltage category II
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- Designation Shipbuilding approval
- DNV GL-Humidity B
- Output name Switching output
- Typical current consumption 32 mA (24 V DC)
- Connection method Push-in connection
- Noise emission EN 61000-6-4
- DNV GL-Vibration A
- Identification UL 508 Listed
- Conductor cross section AWG 24 ... 12 (flexible)
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- Max. switching current 100 mA (30 V)
- Power consumption ≤ 1 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
- No. of channels 1
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- Conformance CE-compliant
- Stripping length 10 mm
- Temperature coefficient, typical 0.01 %/K
- Housing material PBT
- ATEX II 3 G Ex nA IIC T4 Gc X
- Temperature B
- ECLASS 5.1 27210100
- Minimum switching voltage 1 V
- Status display Yellow LED (switching output)
- Rated insulation voltage 300 V (effective)
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- DNV GL-Temperature B
- UNSPSC 21.0 39121007
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 4.0 27210100
- ECLASS 6.0 27210100
- ECLASS 9.0 27210128
- ETIM 6.0 EC002918
- UNSPSC 11 39121008
- ECLASS 4.1 27210100
- ETIM 4.0 EC002653
- UNSPSC 12.01 39121008
- Certificate DNV GL TAA000021E
- ECLASS 10.0.1 27210128
- ECLASS 7.0 27210120
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- Vibration A
- DNV GL-EMC A
- Humidity B
- ECLASS 11.0 27210128
- UNSPSC 7.0901 39121008
- ECLASS 5.0 27210100
- ETIM 7.0 EC002918
- UNSPSC 6.01 30211506
- UNSPSC 20.0 39121007
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- UNSPSC 18.0 39121007
- China RoHS Environmentally Friendly Use Period = 50 years
- UNSPSC 19.0 39121007
- UNSPSC 13.2 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?