2902055 Phoenix Contact Electrical Measuring & Monitoring Instruments

2902055 on Power Resource International
Phoenix Contact

Part#:2902055

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Screw connection technology, standard configuration

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2902055 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    109.81 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • ECLASS 5.0
    27200200
  • ECLASS 5.1
    27200200
  • UNSPSC 12.01
    39121008
  • UNSPSC 20.0
    41112105
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Number of outputs
    1
  • Max. output voltage
    approx. 12.3 V
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Power consumption
    ≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
  • Screw thread
    M3
  • Overvoltage category
    II
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • ATEX
     II 3 G Ex nA IIC T4 Gc X
  • Conformance
    CE-compliant
  • Certificate
    DNV GL 14445-15HH
  • ECLASS 7.0
    27200206
  • ECLASS 6.0
    27200200
  • UNSPSC 7.0901
    39121008
  • UNSPSC 6.01
    30211506
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Configurable/programmable
    Yes
  • Degree of protection
    IP20 (not assessed by UL)
  • Voltage output signal
    0 V ... 5 V (via DIP switch)
  • Ripple
    < 10 mVrms
  • Stripping length
    10 mm
  • Torque
    0.5 Nm ... 0.6 Nm
  • Protective circuit
    Transient protection
  • Rated insulation voltage
    300 V (effective)
  • Housing material
    PBT
  • Mounting position
    any
  • UL, USA/Canada
    UL 508 Listed
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ETIM 2.0
    EC001446
  • ETIM 6.0
    EC002919
  • UNSPSC 13.2
    41112105
  • Depth
    119.2 mm
  • Sensor types that can be used (TC)
    B, C, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
  • Current output signal
    0 mA ... 20 mA (via DIP switch)
  • Short-circuit current
    < 31.5 mA
  • Degree of pollution
    2
  • Noise emission
    EN 61000-6-4
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27200200
  • ECLASS 9.0
    27210129
  • ETIM 4.0
    EC001446
  • UNSPSC 11
    39121008
  • UNSPSC 18.0
    41112105
  • Temperature measuring range
    -250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
  • Load/output load voltage output
    ≥ 10 kΩ
  • Load/output load current output
    ≤ 600 Ω (at 20 mA)
  • Typical current consumption
    32.7 mA (24 V DC)
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Typical deviation from the measuring range final value
    0.05 %
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Connection method
    Screw connection
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • Max. output current
    24.6 mA
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • ECLASS 11.0
    27210129
  • UNSPSC 21.0
    41112105
  • Width
    6.2 mm
  • Typical cold point errors
    2 K (2 K + (0,2 K * ΔT))
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Standards/regulations
    EN 61000-4-6
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm² (with ferrule)
  • ETIM 7.0
    EC002919
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Maximum temperature coefficient
    ≤ 0.01 %/K
  • Designation
    Shipbuilding approval
  • Identification
    C, EMC2
  • ECLASS 4.1
    27200200
  • ETIM 3.0
    EC001446
  • UNSPSC 19.0
    41112105
  • Transmission error thermocouples
    0.1% * 600 K / set measuring range; 0.1% > 600 K (C, E, J, K, N, T, L, U, M Gost, L Gost)
  • ECLASS 10.0.1
    27210129

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?