3-way signal conditioner with plug-in connection technology for the electrical isolation of unipolar and bipolar analog signals. Input signal: 0 ... 10 V/±10 V, output signal: 0 ... 10 V/±10 V, screw connection technology

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2902042 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Height
    109.81 mm
  • Number of inputs
    1
  • Number of outputs
    1
  • Max. output voltage
    11 V
  • Transmission Behavior
    1:1 to input signal
  • Stripping length
    10 mm
  • Maximum temperature coefficient
    0.01 %/K
  • Maximum transmission error
    0.1 % (of final value)
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Housing material
    PBT
  • Depth
    119.2 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Short-circuit current
    < 15 mA
  • Nominal supply voltage
    24 V DC
  • Typical current consumption
    25 mA (24 V DC)
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Temperature coefficient, typical
    0.01 %/K
  • Protective circuit
    Transient protection
  • Identification
    UL 508 Listed
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Load/output load voltage output
    ≥ 10 kΩ
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Power consumption
    ≤ 200 mW (at 9.6 V DC)
  • Screw thread
    M3
  • Step response (10-90%)
    approx. 10 ms
  • Degree of pollution
    2
  • Noise emission
    EN 61000-6-4
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Certificate
    DNV GL TAA00002UA
  • Humidity
    B
  • EMC
    A
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 6.0
    27210100
  • UNSPSC 7.0901
    39121004
  • UNSPSC 21.0
    39121008
  • Width
    6.2 mm
  • Maximum altitude
    ≤ 2000 m
  • Configurable/programmable
    no
  • Voltage output signal
    0 V ... 10 V
  • Connection method
    Screw connection
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm² (with ferrule)
  • Torque
    0.5 Nm ... 0.6 Nm
  • Limit frequency (3 dB)
    approx. 30 Hz
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • Color
    gray
  • Designation
    Shipbuilding approval
  • Vibration
    A
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 4.0
    27210100
  • ECLASS 7.0
    27210120
  • ETIM 6.0
    EC002653
  • UNSPSC 18.0
    39121008
  • Degree of protection
    IP20 (not assessed by UL)
  • Input resistance of voltage input
    approx. 1 MΩ
  • Voltage input signal
    0 V ... 10 V
  • Ripple
    < 20 mVPP (at 10 kΩ)
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • No. of channels
    1
  • Overvoltage category
    II
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Standards/regulations
    EN 61000-4-6
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27210100
  • ETIM 7.0
    EC002653
  • UNSPSC 11
    39121004
  • UNSPSC 19.0
    39121008
  • UNSPSC 20.0
    39121008
  • Rated insulation voltage
    300 V (effective)
  • Mounting position
    any
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Temperature
    B
  • ECLASS 11.0
    27210120
  • ECLASS 5.1
    27210100
  • ETIM 4.0
    EC002653
  • UNSPSC 12.01
    39121004
  • ECLASS 10.0.1
    27210120
  • ECLASS 5.0
    27210100
  • ECLASS 9.0
    27210120
  • UNSPSC 6.01
    30211502
  • UNSPSC 13.2
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?