2902040 Phoenix Contact Electrical Measuring & Monitoring Instruments

2902040 on Power Resource International
Phoenix Contact

Part#:2902040

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover, for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. push-in connection technology, standard c

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2902040 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Depth
    119.2 mm
  • Number of inputs
    1
  • Max. input current
    24 mA
  • Voltage output signal
    0 V ... 5 V (via DIP switch)
  • No. of channels
    1
  • Protective circuit
    Transient protection
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Number of outputs
    1
  • Max. output current
    22 mA
  • Ripple
    < 20 mVPP (at 600 Ω)
  • Power consumption
    ≤ 800 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Height
    109.81 mm
  • Input resistance current input
    approx. 63 Ω (+0.7 V for test diode)
  • Current output signal
    0 mA ... 20 mA (via DIP switch)
  • Load/output load current output
    ≤ 600 Ω (at 20 mA)
  • Typical current consumption
    25 mA (Current output, at 24 V DC incl. load)
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • Temperature coefficient, typical
    0.01 %/K
  • Overvoltage category
    II
  • ECLASS 5.0
    27210100
  • UNSPSC 6.01
    30211502
  • UNSPSC 18.0
    39121008
  • max. input voltage
    33 V
  • Nominal supply voltage
    24 V DC
  • Stripping length
    10 mm
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm² (with ferrule)
  • Step response (10-90%)
    < 8.5 ms (with 30 Hz filter)
  • EMC
    A
  • ECLASS 4.0
    27210100
  • ECLASS 7.0
    27210120
  • ETIM 6.0
    EC002653
  • UNSPSC 20.0
    39121008
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Voltage input signal
    0 V ... 5 V (via DIP switch)
  • Input resistance of voltage input
    > 1000 kΩ
  • Short-circuit current
    < 32 mA
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Limit frequency (3 dB)
    30 Hz (via DIP switch)
  • Degree of pollution
    2
  • Housing material
    PBT
  • Designation
    Shipbuilding approval
  • Temperature
    B
  • ECLASS 10.0.1
    27210120
  • ECLASS 6.0
    27210100
  • UNSPSC 11
    39121004
  • UNSPSC 21.0
    39121008
  • Maximum temperature coefficient
    0.01 %/K
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Rated insulation voltage
    300 V (effective)
  • Noise emission
    EN 61000-6-4
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Certificate
    DNV GL TAA00002UA
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 5.1
    27210100
  • ETIM 4.0
    EC002653
  • UNSPSC 7.0901
    39121004
  • UNSPSC 13.2
    39121008
  • UNSPSC 19.0
    39121008
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Mounting position
    any
  • Identification
    UL 508 Listed
  • Standards/regulations
    EN 61000-4-6
  • Humidity
    B
  • ECLASS 11.0
    27210120
  • ECLASS 4.1
    27210100
  • ECLASS 9.0
    27210120
  • ETIM 7.0
    EC002653
  • UNSPSC 12.01
    39121004
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Connection method
    Push-in connection
  • Width
    6.2 mm
  • Current input signal
    0 mA ... 20 mA (via DIP switch)
  • Degree of protection
    IP20 (not assessed by UL)
  • Maximum transmission error
    ≤ 0.1 % (of final value)
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • Configurable/programmable
    Yes
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Load/output load voltage output
    ≥ 10 kΩ
  • Vibration
    A
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Color
    gray
  • REACh SVHC
    Lead 7439-92-1

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts