3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. Input signal: 0(4) mA ... 20 mA, output signal: 0(4) mA ... 20 mA, screw connection technology

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2901998 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Transmission Behavior
    1:1 to input signal
  • Screw thread
    M3
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Number of inputs
    1
  • Maximum transmission error
    0.1 % (of final value)
  • Configurable/programmable
    no
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Rated insulation voltage
    300 V (effective)
  • EMC
    A
  • Max. output current
    22 mA
  • Power consumption
    ≤ 800 mW (at 9.6 V DC)
  • Number of outputs
    1
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Width
    6.2 mm
  • Current output signal
    0 mA ... 20 mA
  • Nominal supply voltage
    24 V DC
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Limit frequency (3 dB)
    approx. 30 Hz
  • Degree of pollution
    2
  • Temperature
    B
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 4.1
    27210100
  • Housing material
    PBT
  • ECLASS 7.0
    27210120
  • Height
    109.81 mm
  • Degree of protection
    IP20 (not assessed by UL)
  • Overvoltage category
    II
  • Input resistance current input
    approx. 63 Ω (+0.7 V for test diode)
  • Load/output load current output
    ≤ 600 Ω (at 20 mA)
  • Typical current consumption
    25 mA (24 V DC)
  • Connection method
    Screw connection
  • Torque
    0.5 Nm ... 0.6 Nm
  • Temperature coefficient, typical
    0.01 %/K
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm² (with ferrule)
  • Protective circuit
    Transient protection
  • Depth
    119.2 mm
  • Maximum altitude
    ≤ 2000 m
  • Current input signal
    0 mA ... 20 mA
  • Ripple
    < 20 mVPP (at 600 Ω)
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • Noise emission
    EN 61000-6-4
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Standards/regulations
    EN 61000-4-6
  • Humidity
    B
  • ECLASS 11.0
    27210120
  • ECLASS 9.0
    27210120
  • Stripping length
    10 mm
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • No. of channels
    1
  • Step response (10-90%)
    approx. 10 ms
  • ETIM 6.0
    EC002653
  • UNSPSC 18.0
    39121008
  • Color
    gray
  • Vibration
    A
  • ECLASS 10.0.1
    27210120
  • UNSPSC 21.0
    39121008
  • UNSPSC 13.2
    39121008
  • UNSPSC 7.0901
    39121004
  • Maximum temperature coefficient
    0.01 %/K
  • Designation
    Shipbuilding approval
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27210100
  • ETIM 7.0
    EC002653
  • UNSPSC 20.0
    39121008
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Certificate
    DNV GL TAA00002UA
  • ECLASS 6.0
    27210100
  • ECLASS 5.0
    27210100
  • UNSPSC 12.01
    39121004
  • Mounting position
    any
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27210100
  • UNSPSC 6.01
    30211502
  • UNSPSC 11
    39121004
  • UNSPSC 19.0
    39121008
  • Identification
    UL 508 Listed
  • ETIM 4.0
    EC002653
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts