Radioline - 2.4 GHz wireless transceiver with RS-232/RS-485 interface, can be extended with I/O modules, RSMA (female) antenna connection, point-to-point, star, and mesh networks up to 250 stations, range of up to 5 km (with a clear line of sight), for wo
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Data & Networking Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2901541 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 228.75 g
- UNSPSC 18.0 43222604
- UNSPSC 11 39121008
- UNSPSC 12.01 43223108
- UNSPSC 21.0 43222604
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- PLC/Modbus RTU mode ≤ 99 (I/O extension modules per wireless network, access to extension modules via Modbus RTU protocol)
- Contact type Changeover contact
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section solid max. 2.5 mm²
- Number of possible extension modules ≤ 32 (per wireless module)
- Connection technology 2-conductor
- Stripping length 7 mm
- Conductor cross section flexible min. 0.2 mm²
- Certificate B1317250719AE01A2
- Maximum switching voltage 30 V AC/DC
- Conductor cross section AWG min. 24
- Status display Green LED (supply voltage, PWR)
- Height 116 mm
- Operating mode I/O data (Default setting, configuration via thumbwheel)
- MTTF 778 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
- Transmit capacity, minimum 0 dBm
- Range ± 5 km (The range may be considerably above or below that stated, and depends on the environment, antenna technology, and the product used)
- Number of supported devices ≤ 250 (Addressing via PSI-CONF software)
- Connection method Screw connection
- Contact material PdRu, gold-plated
- Max. switching current 500 mA (30 V AC/DC)
- Tightening torque 0.6 Nm
- Identification ISA-S71.04-1985 G3 Harsh Group A
- Depth 114.5 mm
- Permissible humidity (storage/transport) 20 % ... 85 %
- Degree of pollution 2
- Direction Bi-directional
- Comments Criterion B
- Width 17.5 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Number of channels per group 55
- Termination resistor 390 Ω (switchable via DIP switches)
- Number of outputs 1
- Indirect discharge ± 6 kV
- Standards/specifications Ex Directive (ATEX) EN 60079-0
- Degree of protection IP20
- Altitude 2000 m
- Frequency range 0.15 MHz ... 80 MHz
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -40 °C ... 70 °C (>55°C derating)
- Set consists of 2709561 ME 17,5 TBUS 1,5/ 5-ST-3,81 GN
- Flammability rating according to UL 94 V0
- Receiver sensitivity -106 dBm (16 kbps)
- Interface 1 RS-232
- Interface 3 Configuration interface
- Voltage output signal 0 V ... 3 V
- Standards/regulations EN 61000-4-6
- Interface description Trusted Wireless
- ECLASS 6.0 19179200
- ECLASS 7.0 19179290
- ETIM 7.0 EC000310
- Max. current consumption ≤ 65 mA (at 24 V DC, at 25 °C, stand-alone)
- Assembly instructions on standard DIN rail NS 35 in accordance with EN 60715
- Number of channel groups 8
- Transient surge protection Yes
- Data rate 300 bps / 600 bps / 1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps / 19.2 kbps / 38.4 kbps / 57.6 kbps / 93.75 kbps / 115.2 kbps / 187.5 kbps
- Security 128-bit data encryption
- Interface 2 RS-485
- I/O data mode ≤ 99 (I/O extension modules per wireless network, serial interfaces deactivated)
- Serial data mode 0 (no I/O extension modules can be used)
- Conductor cross section flexible max. 2.5 mm²
- Screw thread M3
- Contact discharge ± 6 kV (Test Level 3)
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 19179090
- ECLASS 9.0 19179290
- UNSPSC 6.01 30211506
- UNSPSC 19.0 43222604
- Permissible humidity (operation) 20 % ... 85 %
- Shock 16g, 11 ms
- Overvoltage category II
- Supply voltage range 19.2 V DC ... 30.5 V DC
- Vibration (operation) in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz
- Housing material PA 6.6-FR
- Electrical service life 5x 105 switching cycles with 0.5 A at 30 V DC
- Conductor cross section AWG max. 14
- Additional text ISC directive RSS 210
- Signal ± 1 kV (asymmetrical)
- ECLASS 10.0.1 19179290
- ECLASS 4.1 27230200
- ETIM 4.0 EC000310
- Antenna connection RSMA (female)
- Frequency 2400 MHz
- Channel distance 1.3 MHz
- Transmit capacity, maximum ≤ 20 dBm (Outside of Europe, adjustable via software)
- Transmission length ≤ 1200 m
- Designation Corrosive gas test
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.0 27242200
- ETIM 3.0 EC001423
- UNSPSC 7.0901 43223108
- UNSPSC 20.0 43222604
- Export note *The range may be considerably above or below that stated. It is dependent on the environment, antenna technology, transmission power, and the product used.
- ECLASS 5.1 27242200
- ECLASS 4.0 27230200
- ETIM 6.0 EC000310
- UNSPSC 13.2 43222604
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?