2901422 Phoenix Contact Electrical Safety Devices

2901422 on Power Resource International
Phoenix Contact

Part#:2901422

Manufacturer:Phoenix Contact

Category:Electrical Safety Devices

Product Lifecycle:Active

Get a quick Quote!

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 120 V AC/DC, plug-in screw terminal blocks

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2901422 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (operation)
    -25 °C ... 55 °C
  • Input voltage range
    110 V AC/DC ... 120 V AC/DC
  • Voltage at input/start and feedback circuit
    ~ 24 V DC
  • Typical release time
    60 ms (when controlled via A1)
  • Max. permissible overall conductor resistance
    50 Ω
  • Minimum switching voltage
    10 V AC/DC
  • Sq. Total current
    72 A2 (ITH2 = I12 + I22 + I32)
  • Mechanical service life
    approx. 107 cycles
  • Mounting position
    any
  • pluggable
    Yes
  • Performance level (PL)
    e
  • Rated surge voltage/insulation
    4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths)
  • Shock
    15g
  • REACh SVHC
    Lead 7439-92-1
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Typical input current at UN
    38 mA
  • Typical response time
    40 ms (man. start)
  • Status display
    Green LED
  • Protective circuit
    Surge protection Varistor 275 VRMS (A1-A2)
  • Contact material
    AgSnO2, + 0.2 µm Au
  • Maximum inrush current
    6 A
  • Mounting type
    DIN rail mounting
  • Connection method
    Screw connection
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Rated insulation voltage
    250 V AC
  • Overvoltage category
    III
  • ECLASS 10.0.1
    27371819
  • ECLASS 9.0
    27371819
  • UNSPSC 11
    39121501
  • UNSPSC 18.0
    39122205
  • Height
    99 mm
  • Max. permissible humidity (storage/transport)
    75 % (on average, 85% infrequently, non-condensing)
  • Input voltage range in reference to UN
    0.85 ... 1.1
  • Typ. starting time with Us
    330 ms (when controlled via A1)
  • Operating voltage display
    Green LED
  • Contact type
    3 enabling current paths
  • Limiting continuous current
    6 A (N/O contact)
  • Switching capacity min.
    100 mW
  • Switching capacity (360/h cycles)
    6 A (24 V DC)
  • Net weight
    178.19 g
  • Conductor cross-section AWG
    24 ... 12
  • Safety Integrity Level (SIL)
    3
  • Standards/regulations
    DIN EN 50178/VDE 0160
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 6.0
    27371800
  • ECLASS 5.1
    27371900
  • UNSPSC 6.01
    30211901
  • UNSPSC 13.2
    39121501
  • UNSPSC 21.0
    39122205
  • Width
    22.5 mm
  • Maximum switching voltage
    250 V AC/DC
  • Interrupting rating (ohmic load) max.
    144 W (24 V DC, τ = 0 ms)
  • Output fuse
    10 A gL/gG NEOZED (N/O contact)
  • Nominal operating mode
    100% operating factor
  • Degree of protection
    IP20
  • Stop category
    0
  • Category
    4
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g
  • ECLASS 11.0
    27371819
  • ECLASS 4.0
    40020600
  • ETIM 3.0
    EC001449
  • ETIM 7.0
    EC001449
  • UNSPSC 20.0
    39122205
  • Depth
    114.5 mm
  • Max. permissible relative humidity (operation)
    75 % (on average, 85% infrequently, non-condensing)
  • Recovery time
    1 s
  • Concurrence
  • Maximum switching frequency
    0.5 Hz
  • Inrush current, minimum
    10 mA
  • Maximum interrupting rating (inductive load)
    48 W (24 V DC, τ = 40 ms)
  • Relay type
    Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
  • Min. degree of protection of inst. location
    IP54
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Designation
    Air clearances and creepage distances between the power circuits
  • Safety Integrity Level Claim Limit (SIL CL)
    3
  • Degree of pollution
    2
  • ECLASS 4.1
    40020600
  • ECLASS 7.0
    27371819
  • ETIM 4.0
    EC001449
  • UNSPSC 12.01
    39121501
  • UNSPSC 19.0
    39122205
  • ECLASS 5.0
    27371900
  • ETIM 6.0
    EC001449
  • UNSPSC 7.0901
    39121501

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?