2882569 Phoenix Contact Electrical Measuring & Monitoring Instruments

2882569 on Power Resource International
Phoenix Contact

Part#:2882569

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

Surge protection in the IP67 screw-on module for measuring sensors, direct mounting with 1/2" NPT outer thread, cable gland for the signal cable, two-stage protective circuit. HART-compatible.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2882569 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Degree of protection
    IP67
  • Housing material
    Zinc die-cast, surface bronzed and nickel-plated
  • Number of positions
    3
  • Width
    33.5 mm
  • Altitude
    ≤ 2000 m (amsl (above mean sea level))
  • Type
    Screw-in module
  • Direction of action
    Line-Line & Line-Earth Ground
  • Operating effective current IC at UC
    ≤ 10 µA
  • Nominal discharge current In (8/20) µs (line-earth)
    10 kA (per path)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 2 MHz
  • Connection method
    Screw connection
  • Connection technology
    Screw connection
  • Height
    33.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Standards for cearances and creepage distances
    IEC 60664-1
  • IEC test classification
    C1
  • Nominal voltage UN
    24 V DC
  • Nominal discharge current In (8/20) µs (line-line)
    10 kA
  • Nominal discharge current In (8/20) µs (shield-earth)
    10 kA (optional)
  • Max. discharge current Imax (8/20) µs maximum (line-line)
    10 kA
  • Nominal pulse current Ian (10/1000) µs (shield-earth)
    100 A
  • Nominal pulse current Ian (10/1000) µs (line-line)
    23 A
  • Output voltage limitation at 1 kV/µs (line-earth) static
    ≤ 450 V (Direct grounding)
  • Residual voltage with Ian (10/1000) µs (line-line)
    ≤ 65 V
  • Voltage protection level Up (line-line)
    ≤ 80 V (C2 - 10 kV / 5 kA)
  • Response time tA (shield-earth)
    ≤ 100 ns
  • Depth
    148 mm
  • Color
    silver
  • Mounting type
    direct screw connection
  • Maximum continuous voltage UC
    40 V DC
  • Rated current
    450 mA (55 °C)
  • Residual current IPE
    ≤ 2 µA
  • Total discharge current Itotal (8/20) µs
    20 kA
  • Max. discharge current Imax (8/20) µs maximum (line-earth)
    10 kA (per path)
  • Max. discharge current Imax (8/20) µs maximum (shield-earth)
    10 kA
  • Output voltage limitation at 1 kV/µs (line-earth) spike
    ≤ 450 V (Direct grounding)
  • Output voltage limitation at 1 kV/µs (line-line) static
    ≤ 55 V
  • Voltage protection level Up (line-earth)
    ≤ 450 V (C2 - 10 kV / 5 kA)
  • Voltage protection level Up (shield-earth)
    ≤ 600 V (C2 - 10 kV / 5 kA)
  • Voltage protection level Up static (line-line)
    ≤ 50 V (C2 - 10 kV / 5 kA)
  • Input attenuation aE, sym.
    typ. 0.5 dB (≤ 1.5 MHz / 50 Ω)
  • Impulse durability (shield-earth)
    C2 - 10 kV/5 kA
  • Impulse durability (line-earth)
    C2 - 10 kV / 5 kA
  • Connection method OUT
    Connection line
  • Conductor cross section AWG
    26 ... 16
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27130800
  • ECLASS 7.0
    27130807
  • ETIM 6.0
    EC000943
  • UNSPSC 12.01
    39121610
  • UNSPSC 18.0
    39121620
  • Pulse discharge current Iimp (10/350) µs
    1 kA
  • Total discharge current Itotal (10/350) µs
    2 kA
  • Nominal pulse current Ian (10/1000) µs (line-earth)
    100 A
  • Output voltage limitation at 1 kV/µs (shield-earth) spike
    ≤ 600 V (optional)
  • Output voltage limitation at 1 kV/µs (line-line) spike
    ≤ 55 V
  • Residual voltage at In (line-line)
    ≤ 55 V
  • Response time tA (line-line)
    ≤ 1 ns
  • Cut-off frequency fg (3 dB), sym. in 50 Ω system
    typ. 6 MHz
  • Resistance per path
    2.2 Ω ±10 %
  • Surge protection fault message
    none
  • Max. required back-up fuse
    500 mA (T)
  • Tightening torque
    0.6 Nm
  • Conductor cross section solid
    0.14 mm² ... 1.5 mm²
  • Standards/specifications
    IEC 61643-21 2002
  • ECLASS 11.0
    27130807
  • ETIM 3.0
    EC000943
  • ECLASS 9.0
    27130807
  • ETIM 4.0
    EC000943
  • UNSPSC 11
    39121610
  • UNSPSC 21.0
    39121620
  • Impulse durability (line-line)
    C2 - 10 kV / 5 kA
  • Connection method IN
    Screw terminal blocks
  • Screw thread
    M3
  • Stripping length
    6 mm
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27130800
  • ECLASS 5.1
    27130800
  • ETIM 2.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 13.2
    39121620
  • Conductor cross section flexible
    0.14 mm² ... 1.5 mm²
  • ECLASS 10.0.1
    27130807
  • ECLASS 4.0
    27130800
  • ECLASS 6.0
    27130800
  • ETIM 7.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 19.0
    39121620
  • UNSPSC 20.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?