2880668 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2880668
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Surge protection in the IP67 screw-on module for measuring sensors, direct mounting with M20 x 1.5 outer thread, cable gland for the signal cable, two-stage protective circuit. HART-compatible.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2880668 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 33.5 mm
- ECLASS 11.0 27130807
- ECLASS 5.1 27130800
- ETIM 6.0 EC000943
- UNSPSC 7.0901 39121610
- Color silver
- Standards/specifications IEC 61643-21 2002
- REACh SVHC Lead 7439-92-1
- ECLASS 7.0 27130807
- ETIM 7.0 EC000943
- UNSPSC 13.2 39121620
- UNSPSC 21.0 39121620
- Conductor cross section AWG 26 ... 16
- ECLASS 10.0.1 27130807
- ECLASS 5.0 27130800
- ECLASS 9.0 27130807
- UNSPSC 6.01 30212010
- UNSPSC 19.0 39121620
- UNSPSC 20.0 39121620
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.0 27130800
- ECLASS 6.0 27130800
- ETIM 3.0 EC000943
- UNSPSC 12.01 39121610
- UNSPSC 18.0 39121620
- Connection method IN Screw terminal blocks
- Screw thread M3
- Conductor cross section solid 0.14 mm² ... 1.5 mm²
- ECLASS 4.1 27130800
- ETIM 4.0 EC000943
- ETIM 2.0 EC000943
- UNSPSC 11 39121610
- Depth 137 mm
- Altitude ≤ 2000 m (amsl (above mean sea level))
- Number of positions 3
- Rated current 450 mA (55 °C)
- Residual current IPE ≤ 2 µA
- Nominal discharge current In (8/20) µs (line-earth) 10 kA (per path)
- Max. discharge current Imax (8/20) µs maximum (line-line) 10 kA
- Max. discharge current Imax (8/20) µs maximum (shield-earth) 10 kA
- Output voltage limitation at 1 kV/µs (line-line) spike ≤ 55 V
- Voltage protection level Up (shield-earth) ≤ 600 V (C2 - 10 kV / 5 kA)
- Response time tA (line-earth) ≤ 100 ns
- Surge protection fault message none
- Conductor cross section flexible 0.14 mm² ... 1.5 mm²
- Ambient temperature (operation) -40 °C ... 85 °C
- Degree of protection IP67
- Type Screw-in module
- Direction of action Line-Line & Line-Earth Ground
- Nominal voltage UN 24 V DC
- Nominal discharge current In (8/20) µs (shield-earth) 10 kA (optional)
- Nominal pulse current Ian (10/1000) µs (line-earth) 100 A
- Nominal pulse current Ian (10/1000) µs (shield-earth) 100 A
- Residual voltage at In (line-line) ≤ 55 V
- Voltage protection level Up static (line-line) ≤ 50 V (C2 - 10 kV / 5 kA)
- Cut-off frequency fg (3 dB), sym. in 50 Ω system typ. 6 MHz
- Resistance per path 2.2 Ω ±10 %
- Nominal pulse current Ian (10/1000) µs (line-line) 23 A
- Output voltage limitation at 1 kV/µs (line-earth) static ≤ 450 V (Direct grounding)
- Response time tA (shield-earth) ≤ 100 ns
- Input attenuation aE, sym. typ. 0.5 dB (≤ 1.5 MHz / 50 Ω)
- Max. required back-up fuse 500 mA (T)
- Connection method Screw connection
- Connection technology Screw connection
- Stripping length 6 mm
- Housing material Zinc die-cast, surface bronzed and nickel-plated
- Standards for cearances and creepage distances IEC 60664-1
- Maximum continuous voltage UC 40 V DC
- Nominal discharge current In (8/20) µs (line-line) 10 kA
- Total discharge current Itotal (8/20) µs 20 kA
- Total discharge current Itotal (10/350) µs 2 kA
- Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 450 V (Direct grounding)
- Output voltage limitation at 1 kV/µs (shield-earth) spike ≤ 600 V (optional)
- Voltage protection level Up (line-line) ≤ 80 V (C2 - 10 kV / 5 kA)
- Response time tA (line-line) ≤ 1 ns
- Impulse durability (shield-earth) C2 - 10 kV/5 kA
- Impulse durability (line-earth) C2 - 10 kV / 5 kA
- Tightening torque 0.6 Nm
- Height 33.5 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Mounting type direct screw connection
- IEC test classification C1
- Operating effective current IC at UC ≤ 10 µA
- Pulse discharge current Iimp (10/350) µs 1 kA
- Max. discharge current Imax (8/20) µs maximum (line-earth) 10 kA (per path)
- Output voltage limitation at 1 kV/µs (line-line) static ≤ 55 V
- Residual voltage with Ian (10/1000) µs (line-line) ≤ 65 V
- Voltage protection level Up (line-earth) ≤ 450 V (C2 - 10 kV / 5 kA)
- Cut-off frequency fg (3 dB), sym. in 150 Ω system typ. 2 MHz
- Impulse durability (line-line) C2 - 10 kV / 5 kA
- Connection method OUT Connection line
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?