Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah

About the manufacturer: Phoenix Contact is one of the manufacturers that offers UPS (DC) that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2866598 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    99 mm
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Buffer time
    Can be set to: 0.5 min; 1 min; 2 min; 3 min; 5 min; 10 min; 15 min; 20 min; 30 min; permanent
  • Power factor (cos phi)
    approx. 0.5
  • Input fuse, integrated
    3.15 A (slow-blow, internal)
  • Nominal output voltage
    12 V DC
  • Efficiency
    > 82 %
  • IQ technology
    no
  • Protection class
    II (in closed control cabinet)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG max.
    12
  • Depth
    107 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Input voltage range DC
    100 V DC ... 350 V DC (UL508: 100...250 V DC)
  • Nominal output current (IN)
    4 A
  • Power loss nominal load max.
    10.5 W
  • Surge protection against internal surge voltages
    < 35 V DC
  • Connection in parallel
    yes
  • Net weight
    0.45 kg
  • Conductor cross section AWG min.
    24
  • Stripping length
    8 mm
  • Width
    67.5 mm
  • Degree of protection
    IP20
  • Max. permissible relative humidity (operation)
    95 % (at 25 °C, non-condensing)
  • Inrush current limiting/I²t
    < 1.1 A2s
  • Mains buffering time
    see diagram
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Residual ripple
    < 50 mVPP
  • Insulation voltage input/output
    4 kV (type test)
  • MTBF (IEC 61709, SN 29500)
    > 728000 h (40 °C)
  • Conductor cross section solid min.
    0.2 mm²
  • Screw thread
    M3
  • Standard - Electrical safety
    EN 60950-1/VDE 0805 (SELV)
  • Rail applications
    EN 50121-4
  • Voltage dips
    EN 61000-4-11
  • ECLASS 10.0.1
    27040705
  • ECLASS 6.0
    27040600
  • ETIM 3.0
    EC000382
  • UNSPSC 6.01
    30211510
  • UNSPSC 11
    39121011
  • UNSPSC 20.0
    39121011
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Current consumption
    0.65 A (230 V AC)
  • Protective circuit
    Varistor
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Maximum power dissipation in no-load condition
    3.8 W
  • Power dissipation battery operation
    2.9 W
  • Feedback voltage resistance
    35 V DC
  • Connection method
    Pluggable COMBICON screw connections
  • Conductor cross section flexible min.
    0.2 mm²
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Safety extra-low voltage
    EN 60950-1 (SELV)
  • Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
    EN 50178
  • Electromagnetic HF field
    EN 61000-4-3
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 11.0
    27040705
  • ECLASS 5.0
    27040600
  • ECLASS 7.0
    27040603
  • ETIM 6.0
    EC000382
  • UNSPSC 12.01
    39121011
  • Installation distance top/bottom
    30 mm / 30 mm
  • Degree of pollution
    2
  • Typical response time
    100 ms
  • Setting range of the output voltage (USet)
    10 V DC ... 16 V DC (AC input voltage available, AC input voltage not available: Output voltage depending on the battery voltage: 13.6 V DC ... 9.6 V DC)
  • Max. capacitive load
    unlimited
  • Output current limit
    max. 7 A
  • Peak switching voltages nominal load
    < 100 mVPP
  • Memory medium
    External, rechargeable battery 1.6 Ah / 2.6 Ah
  • Assembly instructions
    alignable: horizontally 0 mm, vertically 50 mm
  • Conductor cross section flexible max.
    2.5 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • UL approvals
    UL Listed UL 508
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Surge voltage load (surge)
    EN 61000-4-5
  • ECLASS 5.1
    27040600
  • ECLASS 4.1
    27040600
  • ETIM 2.0
    EC000382
  • ETIM 4.0
    EC000382
  • UNSPSC 13.2
    39121011
  • UNSPSC 21.0
    39121011
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Electrostatic discharge
    EN 61000-4-2
  • Conducted interference
    EN 61000-4-6
  • ECLASS 4.0
    27040600
  • ECLASS 9.0
    27040705
  • ETIM 7.0
    EC000382
  • UNSPSC 7.0901
    39121011
  • UNSPSC 18.0
    39121011
  • UNSPSC 19.0
    39121011
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Fast transients (burst)
    EN 61000-4-4
  • REACh SVHC
    Lead 7439-92-1

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?