2865793 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2865793
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Ex i repeater power supply and input isolating amplifier, HART Sends fed or active 0/4-20 mA signals from the Ex area to a load (active or passive) to the safe area. Electrical 3-way isolation; SIL 2, wide range power supply.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2865793 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Degree of protection IP20 (not assessed by UL)
- Voltage drop < 3.5 V (in input isolating amplifier operation)
- Load/output load current output < 600 Ω (20 mA)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Torque 0.5 Nm ... 0.6 Nm
- Max. output current Io 93 mA
- Signal output Current output (active and passive)
- Transmission Behavior 1:1 to input signal
- Supply voltage range 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Connection method Screw connection
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Maximum temperature coefficient < 0.01 %/K
- Degree of pollution 2
- Housing material PA 6.6-FR
- Protocols supported HART
- Max. external capacitance Co 820 nF
- Noise emission EN 61000-6-4
- Identification [Ex ia Ga] IIC/IIB
- Height 112.5 mm
- Maximum altitude ≤ 2000 m
- Transmitter supply voltage > 16 V (20 mA)
- Output ripple < 20 mVrms
- Conductor cross section AWG 24 ... 14
- Status display Green LED (supply voltage)
- HART function Yes
- Max. external inductivity Lo 4 mH
- ATEX II (1) G [Ex ia Ga] IIC/IIB
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 10.0.1 27210120
- Stripping length 7 mm
- ECLASS 5.1 27210100
- ETIM 4.0 EC002653
- UNSPSC 7.0901 39121008
- UNSPSC 12.01 39121008
- Signal input Passive current input, intrinsically safe
- Current output signal 0 mA ... 20 mA (active)
- Power dissipation < 1.1 W (24 V DC / 20 mA)
- No. of channels 1
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Group IIC
- Max. internal capacitance Ci negligible
- Typical deviation from the measuring range final value 1 %
- Overvoltage category II
- Certificate DNV 18.0138 X
- ECLASS 4.0 27210100
- ETIM 7.0 EC002653
- UNSPSC 19.0 39121008
- Current input signal 0 mA ... 20 mA
- Voltage output signal 0 V ... 5 V (internal resistance, 250 Ω, 0.1%)
- Output behavior in the event of an error 0 mA (Cable break in the input)
- Designation INMETRO
- Nominal supply voltage range 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Screw thread M3
- Transmission error, typical < 0.05 % (of final value)
- Maximum transmission error < 0.1 % (of final value)
- Electromagnetic compatibility Conformance with EMC directive
- Color gray
- Max. output voltage Uo 25.2 V
- Max. output power Po 587 mW
- Standards/regulations GB 3626.20
- Conformance CE-compliant, additionally EN 61326
- UL, USA/Canada Class I Div 2; IS for Class I, II, III Div 1
- ECLASS 5.0 27210100
- UNSPSC 11 39121008
- ETIM 6.0 EC002653
- UNSPSC 13.2 39121008
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- IECEx [Ex ia Ga] IIC/IIB
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27210100
- ECLASS 6.0 27210100
- UNSPSC 20.0 39121008
- Depth 114.5 mm
- Interference emission EN 61000-6-4
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Operation Signal conditioner operation
- Input voltage Ui ≤ 30 V
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Max. current consumption < 45 mA (24 V DC / 20 mA)
- Step response (10-90%) < 600 µs (for 4 mA ... 20 mA step)
- UNSPSC 6.01 30211506
- Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
- Safety-related maximum voltage Um 253 V AC/DC (Supply terminals)
- Rated insulation voltage 300 Vrms
- Input current Ii ≤ 150 mA
- ECLASS 11.0 27210120
- ECLASS 7.0 27210120
- Width 17.5 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Max. internal inductance Li negligible
- ECLASS 9.0 27210120
- UNSPSC 18.0 39121008
- Additional text ZP/C031/20
- UNSPSC 21.0 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?