2865654 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2865654
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2865654 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Load/output load current output ≤ 600 Ω (20 mA)
- Contact type 1 changeover contact
- Typical current consumption < 50 mA (24 V DC)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Torque 0.5 Nm ... 0.6 Nm
- Maximum temperature coefficient 0.01 %/K
- Electrical isolation 4-way, between input/output/power supply/switching output
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Maximum altitude ≤ 2000 m
- Width 17.5 mm
- Permissible humidity (operation) typ. 5 % ... 95 % (non-condensing)
- Vibration (operation) 5g, accordance to IEC 60068-2-6
- Max. current output signal 22 mA
- Output name Switching output
- Maximum inrush current 0.5 A (30 V AC)
- Screw thread M3
- Conductor cross section AWG 24 ... 14
- Depth 114.5 mm
- Ambient temperature (operation) -20 °C ... 65 °C
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire
- Configurable/programmable Yes
- Max. voltage output signal ± 11 V
- Mechanical service life 1x 105 cycles
- Power consumption < 1.5 W
- Maximum transmission error 0.1 % (E.g., at Pt 100, 300 K min. span)
- Status display Green LED (supply voltage, PWR)
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Max. internal capacitance Ci 44 nF
- Group IIC
- Additional text mixed circuit
- ECLASS 6.0 27200200
- ETIM 4.0 EC001446
- UNSPSC 20.0 41112105
- UNSPSC 21.0 41112105
- Height 112.5 mm
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Degree of protection IP20 (not assessed by UL)
- Input signal range -1000 mV ... 1000 mV
- Load/output load voltage output ≥ 10 kΩ
- Maximum switching voltage 30 V AC (30 V DC)
- Supply voltage range 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Stripping length 7 mm
- Degree of pollution 2
- Electromagnetic compatibility Conformance with EMC directive
- Housing material PA 6.6-FR
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Max. output power Po 11 mW
- ATEX II (1) G [Ex ia Ga] IIC
- IECEx [Ex ia Ga] IIC
- DNV GL-Humidity B
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Shock 15g, according to IEC 60068-2-27
- Temperature measuring range -250 °C ... 2500 °C (Range depending on the sensor type)
- Current output signal 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
- Behavior in the event of a sensor error according to NE 43 or freely configurable
- Contact material AgSnO2, hard gold-plated
- Connection method Screw connection
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Step response (0–99%) typ. 1000 ms (With SIL)
- Interference emission EN 61000-6-4
- Designation INMETRO
- Max. internal inductance Li negligible
- ECLASS 7.0 27200206
- UNSPSC 6.01 30211506
- UNSPSC 12.01 39121008
- UNSPSC 19.0 41112105
- Rated insulation voltage 300 Vrms
- Max. output voltage Uo 6 V
- Safety-related maximum voltage Um 253 V AC/DC
- Typical deviation from the measuring range final value 2 %
- DNV GL-EMC A
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 10.0.1 27210129
- ECLASS 4.1 27200200
- ECLASS 9.0 27210129
- ETIM 3.0 EC001446
- UNSPSC 7.0901 39121008
- ECLASS 5.0 27200200
- ETIM 2.0 EC001446
- ETIM 6.0 EC002919
- UNSPSC 18.0 41112105
- Standards/regulations EN 61000-4-6
- Identification [Ex ia Ga] IIC
- Vibration A
- EMC A
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 11.0 27210129
- Max. output current Io 7.4 mA
- Max. external capacitance Co 21 µF
- Conformance CE-compliant
- DNV GL-Temperature B
- DNV GL-Vibration A
- Temperature B
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 4.0 27200200
- UNSPSC 11 39121008
- UNSPSC 13.2 41112105
- Overvoltage category II
- Color gray
- Max. external inductivity Lo 1 mH
- Noise emission EN 61000-6-4
- UL, USA/Canada UL 508 Listed
- Certificate DNV 18.0143 X
- Humidity B
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27200200
- ETIM 7.0 EC002919
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?