2865476 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2865476
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Ex i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2865476 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 12.5 mm
- Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
- Maximum altitude ≤ 2000 m
- Switching hysteresis < 0.2 mA
- Available input sources NAMUR proximity sensors (IEC/EN 60947-5-6)
- Contact type 1 N/O contact per channel
- Power dissipation < 1 W
- Screw thread M3
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Color gray
- Rated insulation voltage 300 Vrms
- Safety Integrity Level (SIL) 2
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Switching points (unattenuated) > 2.1 mA (conductive)
- Line fault detection Break 0.05 mA < IIN < 0.35 mA
- Maximum switching voltage 250 V AC (2 A)
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Stripping length 7 mm
- No. of channels 2
- Overvoltage category III
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Integrity requirement IEC 61508 - Low demand
- Non-load voltage ~ 8 V DC
- Short-circuit current ~ 8 mA
- Switching output Relay output
- Mechanical service life 107 cycles
- Connection method Screw connection
- Depth 114.5 mm
- Conductor cross section AWG 24 ... 14
- Status display Green LED (supply voltage)
- Housing material PA 6.6-FR
- Degree of pollution 2
- λDD 6 x 10-9 (6 FIT)
- Group IIC
- Max. output current Io 10 mA
- Noise emission EN 61000-6-4
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Degree of protection IP20 (not assessed by UL)
- Signal input Intrinsically safe
- Maximum switching capacity 500 VA
- Switching frequency ≤ 20 Hz (without load)
- Power consumption 0.8 W
- Electromagnetic compatibility Conformance with EMC directive
- Interference emission EN 61000-6-4
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Height 112.5 mm
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Noise immunity EN 61000-6-2 EN 61326
- Switching points (attenuated) < 1.2 mA (blocking)
- Contact material AgSnO2, hard gold-plated
- Nominal supply voltage 24 V DC -20 % ... +25 %
- Max. current consumption 35 mA (24 V DC)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Torque 0.5 Nm ... 0.6 Nm
- Designation EAC Ex
- EMC B
- UNSPSC 19.0 39121008
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Max. internal capacitance Ci 11 nF
- ATEX II (1) G [Ex ia Ga] IIC
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Temperature B
- ECLASS 10.0.1 27210121
- ETIM 2.0 EC001485
- ETIM 4.0 EC001485
- UNSPSC 7.0901 39121008
- Equipment type Type A
- λSD 1 x 10-9 (1 FIT)
- Probability of a hazardous failure on demand (PFDAVG) 3.01 x 10-4 (1 year)
- Additional text and EN 61326
- Standards/regulations GB 3626.20
- DNV GL-EMC B
- Vibration A
- ECLASS 4.1 27210100
- ECLASS 5.1 27210100
- ECLASS 9.0 27210121
- ETIM 6.0 EC001485
- UNSPSC 18.0 39121008
- Safe Failure Fraction (SFF) 78 %
- λDU 6.2 x 10-8 (62 FIT)
- Max. internal inductance Li negligible
- Max. output power Po 25 mW
- Evaluation criterion A
- IECEx [Ex ia Ga] IIC
- DNV GL-Temperature B
- Certificate RU C-DE.AB72.B.00093/19
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 11.0 27210121
- ECLASS 4.0 27210100
- ETIM 3.0 EC001485
- UNSPSC 11 39121008
- UNSPSC 21.0 39121008
- Diagnostic coverage (DC) DCS = 0.4 %, DCD = 8 %
- Max. external inductivity Lo 10 µH
- Safety-related maximum voltage Um 253 V AC (125 V DC)
- UL, USA/Canada Class I Div 2; IS for Class I, II, III Div 1
- Identification [Ex ia Ga] IIC
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27210100
- ECLASS 7.0 27210121
- UNSPSC 6.01 30211506
- UNSPSC 20.0 39121008
- λSU 2.48 x 10-7 (248 FIT)
- Max. output voltage Uo 9.6 V
- Max. external capacitance Co 1 µF
- Conformance CE-compliant, additionally EN 61326
- DNV GL-Humidity B
- DNV GL-Vibration A
- Humidity B
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 6.0 27210100
- ETIM 7.0 EC001485
- UNSPSC 12.01 39121008
- UNSPSC 13.2 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?