2865450 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2865450
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2865450 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Switching points (attenuated) < 1.2 mA (blocking)
- Line fault detection Break 0.05 mA < IIN < 0.35 mA
- Contact material AgSnO2, hard gold-plated
- Nominal supply voltage 24 V DC -20 % ... +25 %
- Stripping length 7 mm
- Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Switching frequency ≤ 20 Hz (without load)
- Power consumption < 950 mW
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Torque 0.5 Nm ... 0.6 Nm
- Electromagnetic compatibility Conformance with EMC directive
- Overvoltage category III
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Safe Failure Fraction (SFF) 78 %
- Probability of a hazardous failure on demand (PFDAVG) 3.01 x 10-4 (1 year)
- Max. internal capacitance Ci 11 nF
- Max. output power Po 25 mW
- Max. external capacitance Co 1 µF
- Safety-related maximum voltage Um 253 V AC (125 V DC)
- ATEX II (1) G [Ex ia Ga] IIC
- Conformance CE-compliant, additionally EN 61326
- Maximum switching capacity 500 VA
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Max. current consumption 30 mA (24 V DC)
- Screw thread M3
- Color gray
- Degree of pollution 2
- Rated insulation voltage 300 Vrms
- Equipment type Type A
- λDD 6 x 10-9 (6 FIT)
- UNSPSC 19.0 39121008
- Width 12.5 mm
- Designation EAC Ex
- Safety Integrity Level (SIL) 2
- λSD 1 x 10-9 (1 FIT)
- Max. internal inductance Li negligible
- Max. output current Io 10 mA
- Max. external inductivity Lo 10 µH
- Group IIC
- Mechanical service life 107 cycles
- Power dissipation < 950 mW
- Connection method Screw connection
- Conductor cross section AWG 24 ... 14
- Housing material PA 6.6-FR
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- DNV GL-EMC B
- Certificate RU C-DE.AB72.B.00093/19
- Integrity requirement IEC 61508 - Low demand
- λSU 2.48 x 10-7 (248 FIT)
- λDU 6.2 x 10-8 (62 FIT)
- DNV GL-Humidity B
- Temperature B
- Vibration A
- ECLASS 11.0 27210121
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Non-load voltage ~ 8 V DC
- Short-circuit current ~ 8 mA
- Switching hysteresis < 0.2 mA
- No. of channels 1
- UL, USA/Canada Class I Div 2; IS for Class I, II, III Div 1
- Switching points (unattenuated) > 2.1 mA (conductive)
- Maximum switching voltage 250 V AC (2 A)
- Interference emission EN 61000-6-4
- Identification [Ex ia Ga] IIC
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Available input sources NAMUR proximity sensors (EN 60947-5-6)
- Switching output Relay output
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Height 112.5 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Noise immunity EN 61000-6-2 EN 61326
- Signal input Intrinsically safe
- Contact type 2 N/O contacts
- Depth 114.5 mm
- Maximum altitude ≤ 2000 m
- Degree of protection IP20 (not assessed by UL)
- Status display Green LED (supply voltage)
- Noise emission EN 61000-6-4
- DNV GL-Temperature B
- EMC B
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 5.0 27210100
- ECLASS 5.1 27210100
- IECEx [Ex ia Ga] IIC
- Humidity B
- ECLASS 10.0.1 27210121
- ECLASS 6.0 27210100
- ETIM 2.0 EC001485
- ETIM 6.0 EC001485
- UNSPSC 18.0 39121008
- Standards/regulations GB 3626.20
- DNV GL-Vibration A
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27210100
- ECLASS 7.0 27210121
- ETIM 3.0 EC001485
- ETIM 4.0 EC001485
- UNSPSC 7.0901 39121008
- UNSPSC 13.2 39121008
- UNSPSC 20.0 39121008
- Diagnostic coverage (DC) DCS = 0.4 %, DCD = 8 %
- Max. output voltage Uo 9.6 V
- Additional text and EN 61326
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.0 27210100
- ECLASS 9.0 27210121
- UNSPSC 6.01 30211506
- UNSPSC 11 39121008
- UNSPSC 21.0 39121008
- ETIM 7.0 EC001485
- UNSPSC 12.01 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?