2865382 Phoenix Contact Electrical Measuring & Monitoring Instruments

2865382 on Power Resource International
Phoenix Contact

Part#:2865382

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, screw connection, up to SIL 3, PL

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2865382 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Max. diameter
    2.3 mm
  • Maximum temperature coefficient
    < 0.01 %/K
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Interference emission
    EN 61000-6-4
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • Ambient temperature (operation)
    -20 °C ... 60 °C (Any mounting position)
  • Current input signal
    4 mA ... 20 mA
  • Transmission Behavior
    1:1 to input signal
  • Group
    IIC
  • ATEX
     II (1) G [Ex ia Ga] IIC
  • IECEx
    [Ex ia Ga] IIC
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Certificate
    DNV 18.0140 X
  • Signal input
    Intrinsically safe
  • Maximum altitude
    ≤ 2000 m
  • Current output signal
    4 mA ... 20 mA (active)
  • Output behavior in the event of an error
    < 3.6 mA (In the event of cable break at the input (as per NE 43))
  • Power dissipation
    < 1.4 W (at 24 V DC / 20 mA)
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Step response (10-90%)
    < 1.3 ms (for 4 mA ... 20 mA step)
  • Housing material
    PA 6.6-FR
  • Designation
    INMETRO
  • Max. output power Po
    587 mW
  • Max. output voltage Uo
    25.2 V
  • Safety-related maximum voltage Um
    253 V AC (125 V DC)
  • DNV GL-Temperature
    B
  • DNV GL-Vibration
    A
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 4.0
    27210100
  • Height
    112.5 mm
  • Width
    12.5 mm
  • Degree of protection
    IP20 (not assessed by UL)
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Load/output load current output
    ≤ 450 Ω (20 mA)
  • Connection method
    Screw connection
  • Stripping length
    7 mm
  • Supply voltage range
    19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
  • Torque
    0.5 Nm ... 0.6 Nm
  • Status display
    Green LED (supply voltage)
  • Rated insulation voltage
    300 Vrms
  • HART function
    Yes
  • Protocols supported
    HART
  • Standards/regulations
    GB 3626.20
  • DNV GL-Humidity
    B
  • Humidity
    B
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 9.0
    27210120
  • ETIM 6.0
    EC002653
  • UNSPSC 12.01
    39121008
  • UNSPSC 20.0
    39121008
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Transmitter supply voltage
    > 16 V (20 mA)
  • Underload/overload signal range
    0 mA ... 24 mA
  • Max. current consumption
    < 100 mA (24 V / 20 mA)
  • No. of channels
    2
  • Conductor cross section AWG
    24 ... 14
  • Maximum transmission error
    < 0.1 % (of final value)
  • Overvoltage category
    II
  • Color
    gray
  • Electrical isolation
    375 V (Peak value in accordance with IEC/EN 60079-11)
  • Max. external inductivity Lo
    100 µH
  • Noise emission
    EN 61000-6-4
  • Conformance
    CE-compliant, additionally EN 61326
  • DNV GL-EMC
    A
  • Temperature
    B
  • EMC
    A
  • ECLASS 10.0.1
    27210120
  • ECLASS 4.1
    27210100
  • UNSPSC 7.0901
    39121008
  • UNSPSC 18.0
    39121008
  • Depth
    114.5 mm
  • Permissible humidity (operation)
    10 % ... 95 % (non-condensing)
  • Signal output
    Current output
  • Nominal supply voltage
    24 V DC
  • Screw thread
    M3
  • Connection name
    Test socket
  • Transmission error, typical
    < 0.05 % (of final value)
  • Degree of pollution
    2
  • Test voltage
    1.5 kV AC (50 Hz, 1 min.)
  • Max. output current Io
    93 mA
  • Max. external capacitance Co
    820 nF
  • Additional text
    and EN 61326
  • UL, USA/Canada
    Class I Div 2; IS for Class I, II, III Div 1
  • Identification
    [Ex ia Ga] IIC/IIB
  • Vibration
    A
  • ECLASS 5.0
    27210100
  • ECLASS 11.0
    27210120
  • ECLASS 5.1
    27210100
  • ETIM 7.0
    EC002653
  • UNSPSC 19.0
    39121008
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 7.0
    27210120
  • ETIM 4.0
    EC002653
  • UNSPSC 6.01
    30211506
  • UNSPSC 21.0
    39121008
  • ECLASS 6.0
    27210100
  • UNSPSC 11
    39121008
  • UNSPSC 13.2
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?