Ex i repeater power supply and input signal conditioner, HART. Transmits supplied or active 0/4 - 20 mA signals from the hazardous area to a load (active or passive) in the safe area. 3-way electrical isolation; SIL 2 according to IEC 61508, with screw co
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2865340 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Transmitter supply voltage > 16 V (20 mA)
- Voltage drop < 3.5 V (in input isolating amplifier operation)
- Nominal supply voltage 24 V DC
- Conductor cross section AWG 24 ... 14
- Maximum transmission error < 0.1 % (of final value)
- Temperature coefficient, typical < 0.004 %/K
- Overvoltage category II
- Polarization and surge protection Yes
- Current output signal 0 mA ... 20 mA (active)
- λDU 5 x 10-8 (50 FIT)
- Diagnostic coverage (DC) DCS=0 %, DCD=0 %
- Max. output voltage Uo 25.2 V
- Max. external capacitance Co 820 nF
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- No. of channels 1
- Step response (10-90%) < 200 µs (for jump 4 mA ... 20 mA, load 600 Ω)
- Interference emission EN 61000-6-4
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Integrity requirement IEC 61508 - High demand
- Input voltage Ui ≤ 30 V
- Standards/regulations GB 3626.20
- UL, USA/Canada UL 61010 Listed
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Humidity B
- Height 112.5 mm
- Maximum altitude ≤ 2000 m
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)
- Transmission Behavior 1:1 to input signal
- Output ripple < 20 mVrms
- Load/output load current output < 1000 Ω (20 mA)
- Torque 0.5 Nm ... 0.6 Nm
- Transmission error, typical < 0.05 % (of final value)
- Degree of pollution 2
- Power consumption < 1.8 W (20 mA / 1000 Ω)
- Connection name Test socket
- Current input signal 0 mA ... 20 mA
- Width 12.5 mm
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Depth 114.5 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Power dissipation < 0.75 W (24 V DC / 20 mA / 1000 Ω)
- Connection method Screw connection
- Nominal supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Stripping length 7 mm
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Max. diameter 2 mm
- Electromagnetic compatibility Conformance with EMC directive
- Color gray
- Protocols supported HART
- Safety Integrity Level (SIL) 2
- Signal output Current output (active and passive)
- Designation INMETRO
- Maximum temperature coefficient < 0.01 %/K
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Equipment type Type A
- λSD 0
- Operation Signal conditioner operation
- Group IIC
- Input current Ii ≤ 150 mA
- Max. internal capacitance Ci negligible
- Noise emission EN 61000-6-4
- DNV GL-Vibration A
- Identification [Ex ia Ga] IIC/IIB
- EMC A
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 4.1 27210100
- ECLASS 6.0 27210100
- ECLASS 7.0 27210120
- ETIM 6.0 EC002653
- UNSPSC 13.2 39121008
- UNSPSC 20.0 39121008
- Degree of protection IP20 (not assessed by UL)
- Max. current consumption < 44 mA (24 V DC / 20 mA / 1000 Ω)
- Screw thread M3
- Status display Green LED (supply voltage)
- HART function Yes
- Safe Failure Fraction (SFF) 90.7 %
- Probability of a hazardous failure per hour (PFHD) 4,99 x 10-8
- Additional text and EN 61326
- Max. internal inductance Li negligible
- DNV GL-Temperature B
- DNV GL-EMC A
- REACh SVHC Lead 7439-92-1
- ECLASS 10.0.1 27210120
- ECLASS 5.0 27210100
- ETIM 4.0 EC002653
- UNSPSC 6.01 30211506
- UNSPSC 21.0 39121008
- Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
- Signal input Passive current input, intrinsically safe
- Output behavior in the event of an error 0 mA (Cable break in the input)
- Housing material PA 6.6-FR
- Rated insulation voltage 300 Vrms
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- λDD 0
- Max. output power Po 587 mW
- Safety-related maximum voltage Um 253 V AC (125 V DC)
- ATEX II (1) G [Ex ia Ga] IIC
- DNV GL-Humidity B
- Temperature B
- Vibration A
- ECLASS 11.0 27210120
- ECLASS 5.1 27210100
- ETIM 7.0 EC002653
- UNSPSC 11 39121008
- UNSPSC 18.0 39121008
- λSU 4.867 x 10-7 (486.7 FIT)
- Probability of a hazardous failure on demand (PFDAVG) 2.40 x 10-4 (1 year)
- Max. output current Io 93 mA
- Max. external inductivity Lo 4 mH
- Typical deviation from the measuring range final value 1 %
- Conformance CE-compliant, additionally EN 61326
- IECEx [Ex ia Ga] IIC
- Certificate DNV 18.0136 X
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.0 27210100
- ECLASS 9.0 27210120
- UNSPSC 7.0901 39121008
- UNSPSC 12.01 39121008
- UNSPSC 19.0 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?