2865010 Phoenix Contact Electrical Measuring & Monitoring Instruments

2865010 on Power Resource International
Phoenix Contact

Part#:2865010

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 isolated relay outputs (N/O contact). Line fault detection (LFD), 3-way electrical isolation, SIL 2, screw connection.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2865010 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (operation)
    -20 °C ... 60 °C (Any mounting position)
  • Noise immunity
    EN 61000-6-2 EN 61326
  • Switching output
    Relay output
  • Height
    112.5 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Short-circuit current
    ~ 8 mA
  • Contact material
    AgSnO2, hard gold-plated
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Non-load voltage
    ~ 8 V DC
  • Switching points (unattenuated)
    > 2.1 mA (conductive)
  • Nominal supply voltage
    24 V DC
  • Power consumption
    < 950 mW
  • Permissible humidity (operation)
    10 % ... 95 % (non-condensing)
  • Available input sources
    NAMUR proximity sensors (EN 60947-5-6)
  • Contact type
    2 N/O contacts
  • Maximum switching voltage
    250 V AC (2 A)
  • Supply voltage range
    19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
  • Stripping length
    7 mm
  • No. of channels
    1
  • Color
    gray
  • Rated insulation voltage
    300 Vrms
  • Integrity requirement
    IEC 61508 - Low demand
  • λSD
    1 x 10-9 (1 FIT)
  • λSU
    2.48 x 10-7 (248 FIT)
  • Noise emission
    EN 61000-6-4
  • DNV GL-Temperature
    B
  • Additional text
    and EN 61326-1
  • Humidity
    B
  • EMC
    B
  • ECLASS 11.0
    27210121
  • ECLASS 7.0
    27210121
  • ETIM 6.0
    EC001485
  • UNSPSC 6.01
    30211506
  • UNSPSC 20.0
    39121008
  • Depth
    114.5 mm
  • Degree of protection
    IP20 (not assessed by UL)
  • Line fault detection
    Break 0.05 mA < IIN < 0.35 mA
  • Mechanical service life
    107 cycles
  • Maximum switching capacity
    500 VA
  • Connection method
    Screw connection
  • Maximum altitude
    ≤ 2000 m
  • Switching points (attenuated)
    < 1.2 mA (blocking)
  • Switching hysteresis
    < 0.2 mA
  • Switching frequency
    ≤ 20 Hz (without load)
  • Max. current consumption
    30 mA (24 V DC)
  • Torque
    0.5 Nm ... 0.6 Nm
  • Housing material
    PA 6.6-FR
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • Degree of pollution
    2
  • Safe Failure Fraction (SFF)
    78 %
  • UL, USA/Canada
    UL 508 Listed
  • DNV GL-Humidity
    B
  • DNV GL-EMC
    B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27210100
  • ECLASS 9.0
    27210121
  • ETIM 3.0
    EC001485
  • UNSPSC 12.01
    39121008
  • UNSPSC 18.0
    39121008
  • Width
    12.5 mm
  • Power dissipation
    < 950 mW
  • Screw thread
    M3
  • Conductor cross section AWG
    24 ... 14
  • Interference emission
    EN 61000-6-4
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Status display
    Green LED (supply voltage)
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Test voltage
    2.5 kV AC (50 Hz, 1 min.)
  • Safety Integrity Level (SIL)
    2
  • Probability of a hazardous failure on demand (PFDAVG)
    3.01 x 10-4 (1 year)
  • Diagnostic coverage (DC)
    DCS = 0.4 %, DCD = 8 %
  • DNV GL-Vibration
    A
  • Identification
    2
  • Certificate
    DNV GL TAA00000AG
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 4.0
    27210100
  • ECLASS 6.0
    27210100
  • ETIM 7.0
    EC001485
  • UNSPSC 11
    39121008
  • UNSPSC 19.0
    39121008
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Designation
    Safety Integrity Level (SIL, IEC 61508)
  • Overvoltage category
    III
  • Equipment type
    Type A
  • λDD
    6 x 10-9 (6 FIT)
  • λDU
    6.2 x 10-8 (62 FIT)
  • Conformance
    CE-compliant, additionally EN 61326-1
  • ATEX
     II 3 G Ex nA nC IIC T4 Gc X
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Temperature
    B
  • Vibration
    A
  • ECLASS 10.0.1
    27210121
  • ECLASS 5.0
    27210100
  • ECLASS 5.1
    27210100
  • ETIM 2.0
    EC001485
  • ETIM 4.0
    EC001485
  • UNSPSC 7.0901
    39121008
  • UNSPSC 13.2
    39121008
  • UNSPSC 21.0
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?