2864655 Phoenix Contact Electrical Measuring & Monitoring Instruments

2864655 on Power Resource International
Phoenix Contact

Part#:2864655

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

MCR passive isolator, 2-channel, for the electrical isolation of current signals without auxiliary power, with screw connection

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2864655 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width
    6.2 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Current input signal
    0 mA ... 20 mA
  • Input voltage limitation
    < 2 V (20 mA)
  • Number of outputs
    2
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Maximum temperature coefficient
    ≤ 0.002 %/K (of measured value / 100 Ω load)
  • Step response (10-90%)
    5 ms (at 600 Ω load)
  • Test voltage input/output
    1.5 kV (50 Hz, 1 min.)
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Connection in acc. with standard
    CUL
  • Humidity
    B
  • ECLASS 11.0
    27210120
  • ECLASS 4.0
    27210100
  • ECLASS 9.0
    27210120
  • ETIM 6.0
    EC002653
  • UNSPSC 13.2
    39121008
  • Depth
    101.2 mm
  • Degree of protection
    IP20
  • Description of the input
    Current input
  • Max. input current
    40 mA
  • Transmission Behavior
    1:1 to input signal
  • Power consumption
    34 mW (per channel)
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Maximum transmission error
    ≤ 0.1 % (of final value)
  • Limit frequency (3 dB)
    75 Hz
  • Degree of pollution
    2
  • Mounting position
    any
  • Standards/regulations
    EN 61000-4-6
  • Identification
    UL 508 Recognized
  • Vibration
    B
  • ECLASS 5.0
    27210100
  • ETIM 4.0
    EC002653
  • UNSPSC 11
    39121008
  • UNSPSC 19.0
    39121008
  • Ambient temperature (operation)
    -20 °C ... 65 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Number of inputs
    2
  • Load/output load current output
    < 600 Ω (at I = 20 mA output signal)
  • Output name
    Current output
  • Ripple
    < 10 mVrms (at 600 Ω)
  • No. of channels
    2
  • Temperature coefficient, typical
    < 0.002 %/K (of measured value / 100 Ω load)
  • Electrical isolation
    Basic insulation according to EN 61010
  • Test voltage channel/channel
    1.5 kV (50 Hz, 1 min.)
  • Housing material
    PBT
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • Designation
    Shipbuilding approval
  • ECLASS 10.0.1
    27210120
  • ECLASS 5.1
    27210100
  • ECLASS 7.0
    27210120
  • UNSPSC 6.01
    30211506
  • UNSPSC 20.0
    39121008
  • Height
    93.1 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • max. input voltage
    18 V
  • Voltage dissipation
    1.9 V (I = 20 mA)
  • Supply voltage range
    no separate supply voltage necessary
  • Stripping length
    12 mm
  • Conductor cross section AWG
    26 ... 12
  • Overvoltage category
    II
  • Color
    green
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Evaluation criterion
    A
  • Certificate
    DNV GL TAA00000BW
  • EMC
    B
  • ECLASS 4.1
    27210100
  • ETIM 7.0
    EC002653
  • UNSPSC 7.0901
    39121008
  • UNSPSC 21.0
    39121008
  • Maximum altitude
    ≤ 2000 m
  • Configurable/programmable
    no
  • Response current
    approx. 190 µA
  • Current output signal
    0 mA ... 20 mA
  • Connection method
    Screw connection
  • Screw thread
    M3
  • Additional error, load-dependent
    < 0.03 % (of measured value / 100 Ω load)
  • Rated insulation voltage
    50 V AC/DC
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Noise emission
    EN 61000-6-4
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Temperature
    B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Enclosure
    A
  • ECLASS 6.0
    27210100
  • UNSPSC 12.01
    39121008
  • UNSPSC 18.0
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts